Monarch EDGE Control Hub configuration
| 48 |
Part # V11470-301-0101
Last updated: July 27, 2020
Configuring Genlock settings
This section describes the
Genlock
settings in
Monarch EDGE Control Hub for the Monarch
EDGE Encoder only. For the Monarch EDGE
Decoder genlock settings, see "
Click
Enable genlock
to synchronize SDI out-
puts to the device’s internal clock. You can gen-
lock your SDI devices/cameras to either an
NTSC-based or PAL-based resolution.
Enable synchronization
with an NTP server
Use an NTP server to update the date and time for your
device at regular intervals. You must provide the
NTP server URL
, even if one is already stored on your
device. For more information on using NTP, contact your
network administrator.
Disable synchronization
with an NTP server
Stop using an NTP server to update the date and time for
your device. Disabling NTP keeps the current date and
time of the device, but it won’t update the devices at regu-
lar intervals.
Time zone
Use current time zone
of the device
Use the time zone currently set for your devices. This is
the default.
Use the following time zone
Change the time zone for your devices to the one selected.
Changing the time zone may adjust the date and time for a
device.
Setting