Administration utility page 229
•
Serial console settings
. Specifies that the serial console should be used as if it were
a telnet session. After you restart the operating system of your Matrox Iris GT,
most of the POST messages will not appear in your serial console. Instead, you
will be prompted to press
Enter
and will be able to interact with your Matrox
Iris GT through your serial console as if it were a regular telnet session.
SNTP and mail client page
The
SNTP and mail client
page allows you to configure the simple network time
protocol (SNTP) for your Matrox Iris GT. SNTP synchronizes the system time
on a computer with that of a server that has been synchronized by a reference
source.
•
SNTP client settings
. Specifies the SNTP settings for your Matrox Iris GT.
Field name
Description
Enable console processor on serial console
Specifies whether the serial console should be used as if it were a telnet session.
Automatically respond to message box with default button
Specifies that any message box that should pop up, due to a serial console
message, will not pop up, and instead the default action will be taken.
Disable GUI message box
Specifies that any message box that should pop up on your desktop should
appear as a text message on the serial console instead.
Button name
Description
Update serial console settings
Accepts changes made for the serial console. Note that the operating system must be restarted for changes
to take effect.
Field name
Description
Enable SNTP
Specifies whether SNTP should be enabled.
SNTP server domain name
Specifies the name of a server that provides the timing signal for SNTP.
Synchronization refresh period
Specifies the number of msecs that your Matrox Iris GT should wait before trying to connect to the SNTP
server and verify the time and date. Refreshing the time of your Matrox Iris GT too often is a waste of
bandwidth resources.
Synchronization retry delay
Specifies the number of msecs that your Matrox Iris GT should wait before it tries to connect to the SNTP
server after the previous attempt failed.
Synchronization threshold
Specifies the acceptable interval, in msecs, between the time on the SNTP server and the current time. If the
difference between the SNTP server time and the current time is less than the SNTP threshold, the current
time on your Matrox Iris GT is not updated.
Button name
Description
Change SNTP settings
Accepts changes made for the SNTP server.
Содержание Iris GT MIL
Страница 1: ...Matrox Iris GT with MIL Installation and Technical Reference Manual no Y11155 201 0110 June 3 2010...
Страница 12: ......
Страница 28: ...28 Chapter 2 Powering and connecting to your Matrox Iris GT...
Страница 40: ...40 Chapter 3 Configuring your Matrox Iris GT to work on a network...
Страница 48: ...48 Chapter 4 Configuring your Matrox Iris GT to work with your computer directly...
Страница 58: ...58 Chapter 5 Accessing Matrox Iris GT...
Страница 83: ...Appendix A Appendix A Glossary This appendix defines some of the specialized terms used in this manual...
Страница 88: ...88 Appendix A Glossary...
Страница 125: ...Appendix F Appendix F The breakout board This appendix describes how to use the Matrox Iris GT breakout board...
Страница 152: ...152 Appendix F The breakout board...
Страница 158: ...158 Appendix G Reading the LEDs...
Страница 238: ...238 Appendix I Matrox Iris portal website details...
Страница 250: ......
Страница 256: ......