52
9.17 HEART RATE BOARD REPLACEMENT
1) Turn off power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.12.
3) The Heart Rate Board is located in front of the red Emergency Stop button (Figure A).
4) Disconnect the wires from each side of the Heart Rate Board (Figure B).
5) Use a Phillips screwdriver to remove two screws, one from each side of the Heart Rate Board mounting bracket (Figure C).
6) Reverse Steps 1-5 to install a new heart rate board.
NOTE:
Be sure to fully seat the wires on the new heart rate board and test the grips
after the console is reinstalled.
FIGURE A
FIGURE B
FIGURE C
CHAPTER 9: PART REPLACEMENT GUIDE
Содержание T5X-04
Страница 1: ...T 5 X 0 4 D E L T A M C B T R E A D M I L L S E R V I C E M A N U A L...
Страница 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION...
Страница 18: ...15 8 1 ELECTRICAL DIAGRAM CHAPTER 8 TROUBLESHOOTING...
Страница 19: ...16 8 1 ELECTRICAL DIAGRAMS P29 Digital Communication Wire CHAPTER 8 TROUBLESHOOTING...
Страница 20: ...17 8 1 ELECTRICAL DIAGRAMS N95 UCB Little Board Wire N97 Hand Pulse Wire CHAPTER 8 TROUBLESHOOTING...
Страница 73: ...70 NOTES...