Emergency Number Dialing
Emergency Number Dialing feature enables user to call emergency services such as Ambulance, Fire Brigade,
Police, etc. in adverse situations. SIMADO GFXD1111S facilitates dialing of emergency numbers through its Mobile
Port. For dialing emergency number, the Mobile Port should be enabled.
Emergency number Dialing will not work if Mains power to SIMADO GFXD1111S fails.
How it Works
In System Firmware Version below V3R22
While dialing out an emergency number, SIMADO GFXD1111S will check emergency number table first. If the
dialed number matches the number programmed in the emergency number table then it will dial out that number
even in following situations:
•
When SIM is absent
•
When SIM is invalid
•
When wrong SIM PIN is entered
•
When SIM is blocked
•
When GSM module is not registered
When SIM is absent or SIM is invalid or wrong SIM PIN is entered or SIM is blocked, GSM module will
consider only those numbers which are available in the GSM module as emergency numbers. By default,
following emergency numbers are available in the GSM module: 000, 08, 112, 110, 911, 999 etc.
In System Firmware Version V3R22 and Higher
When SIMCOM-2G engine (SIM340-B01 or higher) or SIMCOM-3G engine (Version V1.18 or higher) is installed,
SIMADO GFXD1111S will dial out only the numbers available in the Emergency Number Table as emergency
numbers.
SIMADO GFXD1111S will dial out the fixed numbers available in the emergency number table even in the following
situations:
•
When SIM is absent
•
When SIM is invalid
•
When wrong SIM PIN is entered
•
When SIM is blocked
•
When GSM module is not registered
How to Program
•
You can program numbers of your choice in index numbers 1 and 2 of the Emergency Number Table.
You are recommended to program the numbers prevalent as Emergency Numbers in your region, in the
Emergency Number Table.
•
Numbers available in index numbers 3 to 5 are fixed i.e. they are non-programmable.
•
You can program Destination Port for all five Emergency Numbers.
Содержание SIMADO GFXD1111S
Страница 1: ...SIMADO GFXD1111S System Manual...
Страница 2: ......
Страница 3: ...SIMADO GFXD1111S Fixed Cellular Terminal and Router with Data Port System Manual...
Страница 10: ...4 Matrix SIMADO GFXD1111S V3 System Manual...
Страница 24: ...18 Matrix SIMADO GFXD1111S V3 System Manual...
Страница 68: ...62 Matrix SIMADO GFXD1111S V3 System Manual Relevant Topics 1 System Parameters 157 2 Mode of Operation 91...
Страница 80: ...74 Matrix SIMADO GFXD1111S V3 System Manual Relevant Topics 1 System Parameters 157 2 Mode of Operation 91...
Страница 172: ...166 Matrix SIMADO GFXD1111S V3 System Manual...
Страница 187: ...Matrix SIMADO GFXD1111S V3 System Manual 181 Regulatory Information...
Страница 188: ...182 Matrix SIMADO GFXD1111S V3 System Manual...
Страница 189: ...Matrix SIMADO GFXD1111S V3 System Manual 183...
Страница 190: ...184 Matrix SIMADO GFXD1111S V3 System Manual...
Страница 193: ......