34
Error message Inverter error
[Symptom]
Press start then the console display show “INVERTER ERROR “
[Cause]
1. Connector condition of the console cable.
2. Connector condition of the inverter wire .
3. Inverter damage.
[Solution]
1. Check the connector condition of the console cable.
2. Check the connector condition of the inverter wire .
3. Check the inverter display show the which error code and refer the 35 page Faults
displayed list to find the root cause.
4. Replace the inverter.