Three different acquisition modes are available:
Continuous ("Live Mode")
1.
MultiFrame ("Number of Single Snaps")
2.
SingleFrame ("Single Snap")
3.
The frame rate depends on
the camera,
•
the pixel clock of the sensor and
•
the Acquisition Frame Rate.
•
If you want to have a fixed frame rate using the Continuous mode, GenICam offers the property Setting ->
Base -> Camera -> GenICam -> Acquisition Control -> Acquisition Frame Rate (from 5 fps to maximum of
the camera in 0.1 increments). Just adapt this property to your needs.
Alternatively, if you need frame rates below 5 fps, you can use Timers. In the use case Synchronized
acquisitions using timers, for example, a frame rate of 1 fps is generated.rate of 1 fps.
13.4.1.2.2 White balance of a camera device (color version)
Start the wxPropView and initialize the device by clicking Use and start a Continuous acquisition.
Figure 66: wxPropView - Continuous mode
While using a color version of the camera, the PC will calculate a color image from the original gray Bayer
mosaic data. For getting correct colors when working with a Bayer mosaic filter you have to calibrate the
white balance (this must be performed every time the lighting conditions change).
The wxPropView offers predefined settings for e.g.
Daylight,
•
TungstenLamp,
•
HalogenLamp,
•
FluorescentLamp and many more.
•
Simply select the necessary item in the menu Setting -> Base -> ImageProcessing -> WhiteBalance.
If you need a user defined setting, you can also define own ones. For this, select a profile (e.g. User1) for this
setting:
mvBlueLYNX-X Technical Manual
MATRIX VISION GmbH
22 April 2016 Version - 1.49
109
Содержание mvBlueLYNX-X
Страница 1: ...mvBlueLYNX X Technical Manual 22 April 2016 Version 1 49 Copyright 2017 MATRIX VISION GmbH...
Страница 2: ......
Страница 10: ...VIII...
Страница 11: ...1 mvBlueLYNX X Technical Manual MATRIX VISION GmbH 22 April 2016 Version 1 49 1...
Страница 12: ...mvBlueLYNX X Technical Manual 2 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 22: ...mvBlueLYNX X Technical Manual 12 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 24: ...mvBlueLYNX X Technical Manual 14 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 27: ...mvBlueLYNX X Technical Manual MATRIX VISION GmbH 22 April 2016 Version 1 49 17...
Страница 28: ...mvBlueLYNX X Technical Manual 18 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 30: ...mvBlueLYNX X Technical Manual 20 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 50: ...mvBlueLYNX X Technical Manual 40 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 82: ...FrameTime ExposureTime 1000000 mvBlueLYNX X Technical Manual 72 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 108: ...mvBlueLYNX X Technical Manual 98 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 124: ...mvBlueLYNX X Technical Manual 114 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 190: ...mvBlueLYNX X Technical Manual 180 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 213: ...Figure 162 Settings in wxPropView mvBlueLYNX X Technical Manual MATRIX VISION GmbH 22 April 2016 Version 1 49 203...
Страница 214: ...mvBlueLYNX X Technical Manual 204 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 226: ...mvBlueLYNX X Technical Manual 216 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 230: ...mvBlueLYNX X Technical Manual 220 22 April 2016 Version 1 49 MATRIX VISION GmbH...
Страница 236: ...mvBlueLYNX X Technical Manual 226 22 April 2016 Version 1 49 MATRIX VISION GmbH...