and connect the PC and device to it.

Steps for executing a Power On Software Update:

1. Ensure that the 

Software Update Requirements

 are met.

2. Configure the PC for the IP address 192.168.2.58 or another unique IP on the same 192.168.2.x IP 

network (except 192.168.2.59).  Make sure that no other system on the network is using 192.168.2.59 or 
the IP assigned to the PC.

3. Prepare the TFTP program to transfer the firmware file to the device, but do not initiate the transfer yet.  

See the section 

TFTP Software

 for details.

4. Power on the device (power cycle it if it is already on).
5. Immediately after powering on the device, initiate the TFTP transfer (hit ENTER on the tftp command, 

etc), there is only a 5 second time window to initiate the transfer.

6. If the transfer does not complete successfully within 30 seconds, retry from step 3.

4.1.3 Command Software Update

This method uses the device's already assigned IP address and the execution of a Mascot command to initiate 
the software update.  If the IP is unknown, use the 

Power On Software Update

 method or refer to the 

Unknown 

IP 

   A

   ddress

 section.

NOTE:

 The software update time window is 30 seconds for this method, so a cross over cable should be OK, 

but if in doubt, make sure there is an Ethernet switch between the device and update PC.

Steps for executing a Command Software Update:

1. Ensure that the 

Software Update Requirements

 are met.

2. Configure the PC for a unique IP address on the same IP network as the device (if not already).  Make 

sure that there are no IP conflicts with the PC or device.

3. Prepare the TFTP program to transfer the firmware file to the device, but do not initiate the transfer yet.  

See the section 

TFTP Software

 for details.

4. Power up the device being updated, if not already operating.
5. Use one of the following methods to send a Mascot command to the device:

If the device already contains version 5 firmware (mid year 2011), connect to the device's web page 
interface by using a web browser, entering it's IP address into the browser's Location bar and 
pressing ENTER.  Navigate to the command tab, where the command will be typed into the text 
entry field at the top.

Use a telnet client to connect to port 40 on the device.  For many command line telnet clients 
(Windows XP, Mac OSX, Linux, etc) this can be accomplished by opening up a command terminal 
and typing the following command (replace 192.168.2.60 with the actual IP of the device): “telnet 
192.168.2.60 40”.  Once connected press ENTER and make sure a “>” prompt character is displayed
(indicating that a valid connection has been established).  The software update command can then be
typed in the telnet session.

If the device is a Matrix Switch Corporation router, then you can connect a serial cable between it 
and the PC.  Use a terminal program, such as Hyperterm, and configure the serial settings for 9600 
Baud 8N1 (8 data bits, No parity, 1 stop bit). Press ENTER to confirm the connection (a '>' prompt 
character should be displayed).  The software update command can then by typed in the serial 
connection window.

Page 41 of 48

Copyright © 2013-2015 Matrix Switch Corporation

www.matrix-switch.tv

Содержание MSC-CP32X1E

Страница 1: ...Matrix Switch Corporation MSC CP32X1E Product Manual 1RU 32x1 Remote Elastomeric Button Panel Revision 1 2 Page 1 of 48 2013 2015 Matrix Switch Corporation www matrix switch tv...

Страница 2: ...MITED TO ITS CONDITION QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corpo...

Страница 3: ...6 24 Updated External Button Control Pinout section Added External Button Control information for MSC HD42L 2014 03 17 Fixed some document cross references Minor text content and figure position chang...

Страница 4: ...12 2 2 3 Button Panel Settings 13 2 3 Command Tab 13 3 Mascot Control Protocol 15 3 1 Protocol changes 15 3 2 Telnet access 16 3 3 Command format 16 3 3 1 Command names 16 3 3 2 Command arguments 17 3...

Страница 5: ...ars Command 37 3 45 W Command 38 3 46 WebPass Command 38 3 47 X Command 38 4 Software Updates 40 4 1 Software Update on Carina Series Devices 40 4 1 1 Software Update Requirements 40 4 1 2 Power on So...

Страница 6: ...MSC CP32X1E Product Manual 7 Matrix Switch Corporation Warranty 48 Page 6 of 48 Copyright 2013 2015 Matrix Switch Corporation www matrix switch tv...

Страница 7: ...plugged into a suitable AC power source to power it up Once the device is powered it goes through the following startup sequence 5 second startup delay to allow for Power On Software Updates The remo...

Страница 8: ...ngs and physical Ethernet connections In the event that the IP address of the device is unknown refer to the Unknown IP Address troubleshooting section 1 4 2 Network Settings Network settings can be c...

Страница 9: ...g between networks if on separate LANs SECURITY WARNING Matrix Switch Corporation devices are meant for installation in trusted LAN environments In the event that remote device configuration or contro...

Страница 10: ...ions sources and or levels Example use scenarios Utilize an 8x1 remote panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router to c...

Страница 11: ...es to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 System...

Страница 12: ...iptive name of the system up to 15 characters displayed at the top of the Web Page interface which is helpful when managing multiple systems 2 2 2 Network Settings WARNING DHCP should only be enabled...

Страница 13: ...inations of a 16x4 Router 16 source 4 destination Another usage scenario would be to have 2 separate panels control different levels of a Video Audio Router Remote Router IP The IP address of the remo...

Страница 14: ...xt entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all command output in...

Страница 15: ...changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot version 2 4 Carina Series Firmware 5 6 3 Add...

Страница 16: ...space is also not required between command names and their first argument if the argument is numeric Special command characters Multiple command separator for chaining commands CR Carriage Return ASCI...

Страница 17: ...New Line CR LF pair of characters ASCII 13 followed by ASCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive addition...

Страница 18: ...alid argument One or more invalid argument values E04 Invalid destination Invalid matrix destination number E05 Invalid source Invalid matrix source number E06 Invalid level Invalid matrix level numbe...

Страница 19: ...sed as the basic commands such as system configuration commands Mascot protocol versions where a command was added is indicated in parenthesis 2 3 for example Command Arguments Description B 0 1 Reboo...

Страница 20: ...different I O regions of a router PanelRate 2 1 RATE Set remote panel refresh rate in seconds PsetNames PRESET LABEL Query or assign preset names Reboot Reboot the system ReclkDis 2 1 0 1 Disable SDI...

Страница 21: ...label to a destination When querying names labels are surrounded by double quotes and each level is separated by commas multi level systems only and each destination is separated by newlines Secondar...

Страница 22: ...x routing changes echo A value of 0 disables this feature A value of 1 will cause all matrix routing changes to be echoed in the form of an X command Xd s l Where d is the destination number s is the...

Страница 23: ...nd assign the remote Router IP FrameIP 192 168 2 60 FrameIP 192 168 2 61 3 16 Gateway Command Query or assign the network Gateway IP address This is usually only needed on Remote Panel systems which c...

Страница 24: ...atus and rate detection for outputs Format is one decimal number per output 0 Unlocked 1 SD 2 HD Example for a 16x4 system SD HD Unlocked Unlocked LockStatus 1 2 0 0 3 20 MAC Command Query system Ethe...

Страница 25: ...ing of an array of arrays one per level with 3 integer numbers specifying the destination count source count and flags of the level The flags value is the sum of one or more values from the Flags tabl...

Страница 26: ...or preset 8 chars or less TYPE Level type VIDEO AUDIO HD VGA 3G ANALOG or AES Used for general video general audio HD video VGA video 3G HD video analog audio or AES digital audio respectively DEST_C...

Страница 27: ...uping This setting is saved and recalled on power up The I O grouping feature is used to combine multiple inputs and outputs Combined grouped inputs and outputs then behave as if they were a single I...

Страница 28: ...ured to be on the same IP network In the event that the IP address or Netmask of a system is unknown consult the Unknown IP Address section for this device Command Description NetMask Query network ma...

Страница 29: ...1 2 are paired and 3 4 are paired likewise for sources This setting is stored and recalled on power up Command Description PairIO Query current value of I O pairing configuration PairIO 0 1 Enable or...

Страница 30: ...n 0 and LVL2 is 0 then the secondary level control will be disabled Examples PanelOfs 0 0 0 0 PanelOfs 1 0 0 0 PanelOfs 0 0 2 0 The first command just queries the current panel offset values which ret...

Страница 31: ...on panel refresh rate When a button panel is configured to control a remote router the current connection status is refreshed at regular intervals This command can be used to increase or decrease the...

Страница 32: ...ls are surrounded by double quotes and separated by newlines Examples PsetNames Startup Preset1 Preset2 Preset3 Preset4 Preset5 Preset6 Preset7 Preset8 Preset9 PsetNames 1 Preset1 PsetNames 1 MyPreset...

Страница 33: ...umber of system levels Special source values indicates No Change which causes no changes to the given Destination Level 0 indicates Mute Command Description PView Display all presets PView PRESET Disp...

Страница 34: ...e right channels When enabled this option synchronizes matrix crosspoint changes to the router IP address assigned with the FrameIP Command This command should only be enabled with one of the two rout...

Страница 35: ...al port This setting is stored and recalled on power up Command Description Sierra Query Sierra Video Systems protocol enable on serial port Sierra 0 1 Assign Sierra Video Systems protocol enable 0 Di...

Страница 36: ...g to the second level of the first source thereby indicating that the first level label should be used 3 42 SysName Command Query or assign system name The system name is provided for convenience when...

Страница 37: ...are not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 44 Vars Command Protocol Version 2 3 Display all system configuration variables Useful...

Страница 38: ...PRESET Example to save state to preset 1 W 1 3 46 WebPass Command Assign a web password to password protect the web page interface The serial and TCP IP port Mascot protocol control is not protected b...

Страница 39: ...estination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state typical of a 16x4 system for example...

Страница 40: ...he TFTP transfer has to occur within this period after power cycling the device This means the PC needs to be in close proximity of the device remote power control be possible or coordination with som...

Страница 41: ...e IP network as the device if not already Make sure that there are no IP conflicts with the PC or device 3 Prepare the TFTP program to transfer the firmware file to the device but do not initiate the...

Страница 42: ...mands to navigate to the folder where the firmware file is located 4 Type the following command to prepare the TFTP transfer but don t hit ENTER yet tftp 192 168 2 59 put MatrixFirmware x x x hex 5 Ma...

Страница 43: ...type quit and ENTER and start over from step 3 4 2 4 Linux The tftp application can easily be installed with your distributions package manager from a terminal below are some example commands for vari...

Страница 44: ...system s settings will not be retained after the software update This means that all input output labels networking configuration and the Ethernet MAC address will be lost and will need to be re enter...

Страница 45: ...ngrading from version 5 4 0 to a previous version If downgrading from Carina firmware version 5 4 0 or newer to a version prior to 5 4 0 the system configuration will not be retained Please contact Ma...

Страница 46: ...e dip switch is turned off and the system is rebooted or power cycled at which point it will revert to the value stored in the system configuration 5 2 No Ethernet link when connected to network switc...

Страница 47: ...d for audio means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled...

Страница 48: ...rial Authorization RMA number which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or mod...

Отзывы: