LCD0821 rev 2
23
The numbers can also be expressed in decimal form if preferred.
6.3.1 ASCII Characters
Since computers deal internally with numbers only, but externally with both letters and numbers, several
schemes were developed to "map" written characters to numeric values. One such scheme has become
universal, the American Standard Code for Information Interchange, or ASCII. ASCII tables are readily
available from a number of sources. A few examples will do here:
The letter
A
has a value of 65 decimal or
41 hex
The letter
a
has a value of 97 decimal or
61 hex
The number
0
has a value of 48 decimal or
30 hex
The number
9
has a value of 57 decimal or
39 hex
This gives rise to the possibility of confusion when parameters are being set on the LCD0821 For example,
the GPO ON and OFF commands use a number to indicate which GPO is being controlled.
We're told that
acceptable values are 0 to 6.
All such parameters must use numeric values (i.e. the actual byte values).
If we send the ASCII number 0 by mistake it will actually give the value 48 decimal (30 hex) to the
parameter, which is wrong. In the tables given in the following sections ASCII characters are shown as 'A',
with single quotes.
6.4 Text Commands
See Chapter 3 for command descriptions. Syntax in the tables below is given in hex, decimal and decimal
with ASCII, in that order, one per line.
Table 6-1 Text Commands
Command Syntax
Default
Notes
Auto line wrap on
FE 43
254 67
254 'C'
off
Enables line wrapping (not word wrap).
Auto line wrap off
FE 44
254 68
254 'D'
off
Disables line wrapping.
Auto scroll on
FE 51
254 81
254 'Q'
off
Enables scroll at bottom of screen. Text will
push display up one line to make room for new
line.
Auto scroll off
FE 52
254 82
254 'R'
off
Disables auto scroll. Text will wrap to top left
and overwrite existing text.
Set cursor position
FE 47 [col] [row]
254 71 [col] [row]
254 'G' [col] [row]
n/a
Moves cursor to the specified column and row.
The cursor marks the text insertion point in
this and all commands.
Send cursor home
FE 48
254 72
254 'H'
This command moves the cursor to the top left
of the display area.
Underline cursor on
FE 4A
254 74
254 'J'
off
Turns on the underline cursor.
electronic components distributor