CIRCUIT DIAGRAM

A3

A3

Supply

N

N

A1

A2

Contactor 18A 

240Vac

C1

A1

A2

Contactor 18A 

240Vac

C1

L1

T1

L2

T2

L3

T3

Contactor 3P

C1

L1

T1

L2

T2

L3

T3

Contactor 3P

C1

12 Vac

0Vac

95

96

NC Contact

TOL1

95

96

NC Contact

TOL1

Strobe 

Light

Strobe 

Light

Buzzer

Buzzer

EE

Thermal 

Overload

TOL1

Thermal 

Overload

TOL1

Stop 

Level

Stop 

Level

Start 

Level

Start 

Level

High 

Level

High 

Level

1

2

3

4

5

6

O

N

1

2

3

4

5

6

O

N

1

2

3

4

5

6

O

N

1

2

3

4

5

6

O

N

ME 20

BMS

SIGNAL

IN

POWER IN

9-12V DC/AC

PUMP 2

FAULT

PUMP 1

FAULT

HIGH

LEVEL

POWER

VOLTAGE FREE CONTACTS

PCB BMS 1

ME 20

BMS

SIGNAL

IN

POWER IN

9-12V DC/AC

PUMP 2

FAULT

PUMP 1

FAULT

HIGH

LEVEL

POWER

VOLTAGE FREE CONTACTS

PCB BMS 1

Common

Common

14

13

C1 Aux NO

C1

14

13

C1 Aux NO

C1

Power On

Power On

High Level

High Level

Pump Run

Pump Run

Pump Fault

Pump Fault

BM

S

Vo

lt 

Fr

ee

Circuit 

Breaker 2A

CB1

Circuit 

Breaker 2A

CB1

Low 

Level

Low 

Level

240V

240N

12V

0V

Transformer 12Vac

T1

240V

240N

12V

0V

Transformer 12Vac

T1

1

2

3

4

5

6

Main Isolator 

25A 3P

MSW1

1

2

3

4

5

6

Main Isolator 

25A 3P

MSW1

A1

A1 A2

A2

U1

V1

W1

415VAC 

Pump 3P

P1

U1

V1

W1

415VAC 

Pump 3P

P1

P1

P1
P2

P2
P2

P2

Pump

Thermal

Pump

Thermal

Содержание FPC-15207

Страница 1: ...MAIN ISOLATOR OFF ON DOC FPC 15207 VER 1 0 P U M P C O N T R O L OWNER S OPERATION MANUAL Single Pump Controller Installation and Operating Instructions MODEL FPC 15207...

Страница 2: ...ust be Circuit Breaker Protected Qualified Electrician to determine appropriate amp rating Electrical connection to the panel must be carried out in accordance with Connection Instructions see page 3...

Страница 3: ...E VOLTAGE FREE BMS OUTPUTS 415Vac MAINS POWER SUPPLY PUMP PUMP ON STEADY A pump fault overload has occured MOMENTARY PRESS To mute audible buzzer PRESS FOR 3 SECS To reset alarms and faults PRESS CONT...

Страница 4: ...in Manual Mode after 5 minutes the pump will revert to Auto 6 Off High Level Alarm automatically resets upon open circuit of high level input High Level alarm has 15 minute delay On High Level Alarm c...

Страница 5: ...ts This run on occurs even if Pressure switch contacts open during this initial period If however run time exceeds 11 seconds the pump will stop immediately upon open circuit occurring If the Pressure...

Страница 6: ...uit The controller will also use the alternate High Level Alarm Delay Typically used for Storm Water applications High Level Alarm delay in this mode is 15 minutes Setting this DIP Switch to On will c...

Страница 7: ...2V DC AC PUMP 2 FAULT PUMP 1 FAULT HIGH LEVEL POWER VOLTAGE FREE CONTACTS PCB BMS 1 ME 20 BMS SIGNAL IN POWER IN 9 12V DC AC PUMP 2 FAULT PUMP 1 FAULT HIGH LEVEL POWER VOLTAGE FREE CONTACTS PCB BMS 1...

Страница 8: ...LARM ON A high level alarm has been present for the preset time FLASHING A low level alarm is present ON STEADY Pump switched on to run ON STEADY A pump fault overload has occurred FLASHING A prime lo...

Отзывы: