WELCOME TO SINGLE PUMP CONTROL

Your  Single  Pump  Controller  reflects  the  superior  quality  and  attention  to  detail  in  design,  engineering  and

manufacturing that has distinguished MATelec Products for decades. The controller incorporates the very latest in 

micro-processor technology, ensuring you, the owner/operator, of many years of functional, reliable and ‘user friendly’ 

operation.

Please read this manual prior to installation and operation of the controller.

• 

Prior to Installation, ensure power supply is isolated.

• 

Power supply must be Circuit Breaker Protected. (Qualified Electrician to determine appropriate amp rating.)

• 

Electrical connection to the panel must be carried out in accordance with ‘Connection Instructions’, see page 3.

• 

Addition or modifications to the control panel are not permitted and will void warranty.

• 

The controller is not intended for use by children or infirm persons without supervision.

• 

Repairs to the Controller must only be carried out by a suitably qualified Electrician

SAFETY

WARNING: All electrical connections must be carried out by a suitably qualified and

registered electrician

SAFETY 

  2 

CIRCUIT 

DIAGRAM 7

INSTALLATION   

AT A GLANCE   

8

Mounting   

 

 

Indicators

Connection  

 

 

Push Buttons

GETTING STARTED 

4

Operations
Features

CONTENTS

Содержание FPC-15207

Страница 1: ...MAIN ISOLATOR OFF ON DOC FPC 15207 VER 1 0 P U M P C O N T R O L OWNER S OPERATION MANUAL Single Pump Controller Installation and Operating Instructions MODEL FPC 15207...

Страница 2: ...ust be Circuit Breaker Protected Qualified Electrician to determine appropriate amp rating Electrical connection to the panel must be carried out in accordance with Connection Instructions see page 3...

Страница 3: ...E VOLTAGE FREE BMS OUTPUTS 415Vac MAINS POWER SUPPLY PUMP PUMP ON STEADY A pump fault overload has occured MOMENTARY PRESS To mute audible buzzer PRESS FOR 3 SECS To reset alarms and faults PRESS CONT...

Страница 4: ...in Manual Mode after 5 minutes the pump will revert to Auto 6 Off High Level Alarm automatically resets upon open circuit of high level input High Level alarm has 15 minute delay On High Level Alarm c...

Страница 5: ...ts This run on occurs even if Pressure switch contacts open during this initial period If however run time exceeds 11 seconds the pump will stop immediately upon open circuit occurring If the Pressure...

Страница 6: ...uit The controller will also use the alternate High Level Alarm Delay Typically used for Storm Water applications High Level Alarm delay in this mode is 15 minutes Setting this DIP Switch to On will c...

Страница 7: ...2V DC AC PUMP 2 FAULT PUMP 1 FAULT HIGH LEVEL POWER VOLTAGE FREE CONTACTS PCB BMS 1 ME 20 BMS SIGNAL IN POWER IN 9 12V DC AC PUMP 2 FAULT PUMP 1 FAULT HIGH LEVEL POWER VOLTAGE FREE CONTACTS PCB BMS 1...

Страница 8: ...LARM ON A high level alarm has been present for the preset time FLASHING A low level alarm is present ON STEADY Pump switched on to run ON STEADY A pump fault overload has occurred FLASHING A prime lo...

Отзывы: