Mate Pilot™ Turret Calibration System 

Installation and Operation Instructions 

Verification Mode 

Adjustment Handle 

Tensioning Knob 

T-Bar 

Battery Cover 

Tri-color indicator light 

Key Slot 

Mate Pilot™ Turret 
Calibration System 

 
These instructions show the 
operation of the Mate Pilot 
Calibration System in two 
modes. 
 

• 

Verification Mode

Used to confirm the precise 
concentric and angular 
alignment of your turret to 
maintain high quality piece 
parts, extend tool life and 
increase productivity. 

 

• 

Alignment Mode

—Used 

to restore the concentric 
and angular alignment of 
each station with the same 
or better precision as the 
initial machine installation.  
Achieving precise alignment 
improves piece part quality, 
extends tool life, and 
increases productivity. 

 

Verification Mode

 

1. 

Rotate the turret until the station to be verified is in the tool change position and remove punch guide and/or die. 

2. 

Install the lower calibration instrument into the die holder and tighten the clamp screw(s) as you would for a die. 

3. 

Install the upper calibration instrument into upper holder, gently lowering the instrument until the lock pawl (see Figure 1) rests on the top of 
the turret key in the machine. 

Caution

: Do not allow the upper instrument to drop onto the turret key or through the turret bore as this may 

damage the instrument and/or the turret bore.  

4. 

Look into the turret gap to ensure the threaded end of the length adjustment handle is not engaged with the lower calibration instrument. 

5. 

Rotate the turret until the station to be verified is positioned under the ram. Note: The turret must be locked in place. For auto-index 
stations, the auto-index must be engaged. 

6. 

Lower the upper instrument gently, by depressing the release button and lowering the instrument using the adjustment handle, until the 
threaded end of the adjustment handle rests on the top of the lower instrument. 

Caution

: Do not allow the upper instrument to drop onto the 

turret key or through the turret bore as this may damage the instrument and/or the turret bore.  

7. 

Reach into the machine and rotate the T-bar on the adjustment handle until the red light just turns on, then continue rotating with the 
tensioning knob (see Photo 2) until the interlocking teeth of the upper and lower instruments are engaged and the tensioning knob starts to 
click. Do not use the T-bar when any of the lights are on as this may result in a false verification.   

8. 

View the color of the indicator light. If the light is obscured, then view the reflection of the light on the handle. 

• 

Red: angularity and concentricity is not confirmed. Perform an alignment as described on pages 2 and 3. 

• 

Yellow: angularity and concentricity is within 0.0012(0.030) 

• 

Green: angularity and concentricity is within 0.0003(0.008) - ideal for 0.048(1.20) material or less. 

9.       Loosen the adjustment handle until the threaded end of the adjustment handle is fully disengaged from the lower instrument. 
10.     Lift the upper instrument gently, using the length adjustment handle, until the lock pawl rests on the top surface of the turret key.  
11      Look into turret gap to ensure the threaded end of the length adjustment handle is not engaged with the lower instrument. 
12.     Rotate the turret until the station that has been verified is in the tool change position. 
13.  Note: If you did not previously use the alignment mode, then skip this step. Tighten any screws that were previously loosened during  
         alignment in accordance to the punch press manufacturer’s torque specifications.   
14.    Repeat steps 5 to 11 above to ensure the tool holder did not move during tightening.  
15.    Remove the upper and lower instruments. 

Photo 2: Tighten tensioning 
knob on adjustment handle 
until knob starts to click. 

Photo 1: Install upper and 
lower instruments. Rotate 
station under machine ram. 

Photo 3: View Light Color 

Figure 2: 

Engaged, but not aligned 

Angularity and concentricity within 0.0012(0.030) 

Angularity and concentricity within 0.0003(0.008) 

Note: Angularity and concentricity within 0.0003(0.008) - 
Green Indicator Light  - is recommended when punching 
materials with a thicknesses of 0.048(1.20) or less. 

Release Button 

Upper Instrument  

Lower Instrument 

Interlocking Teeth 

Key Slot 

Threaded End of  
Adjustment Handle 

Sensor Contact Surface 

Sensors 

Figure 1: 

Retaining Clip 

Lock Pawl 

Pilot is a trademark of Mate Precision Tooling Inc. 

Содержание Pilot

Страница 1: ...rret key or through the turret bore as this may damage the instrument and or the turret bore 7 Reach into the machine and rotate the T bar on the adjustment handle until the red light just turns on then continue rotating with the tensioning knob see Photo 2 until the interlocking teeth of the upper and lower instruments are engaged and the tensioning knob starts to click Do not use the T bar when ...

Страница 2: ...ment handle is not engaged with the lower calibration instrument See photo 4 Align Lower Holder 1 Rotate the turret until the station to be aligned is under the ram Note The turret must be locked in place For auto index stations the auto index must be engaged 2 Lower the upper instrument gently by depressing the release button and lowering the instrument using the adjustment handle until the threa...

Страница 3: ...machine and tighten the adjustment handle using the T bar until the interlocking teeth of the upper and lower instruments are fully engaged The indicator light will change color from red to yellow and then to green see photo 4 During this process the upper and lower tool holders will be adjusted into precise concentric and angular alignment Caution Do not use any device other than the T bar to tig...

Страница 4: ...wer instrument until the interlocking teeth are fully engaged If the light fails to activate repeat steps 5 and 6 8 Reinstall the cover using the button head screws and wrench used in step 4 9 Reinstall the adjustment handle Install the handle through the upper instrument until the tip protrudes through the underside Replace the clip into the groove on the adjustment handle Use needle nose pliers ...

Отзывы: