INSTALLATION AND ADJUSTMENT
9
§3 Installation and Adjustment
§3.1 Parameters
Model
Parameters
M148 (110VAC)
M208 (220VAC)
Input Voltage
(
V
)
1~110/115
±
10%
1~208-240
±
5%
Input Current
(
A
)
20 (max.)
20 (max.)
Input Power
(
KW
)
4.2
5.7
Welding
Current
(
A
)
35~140 50~200
No-load
Voltage
(
V
)
48
57
Duty cycle
(
4
0
℃)
40%130A 100%95A
25%200A 100%120A
Diameter(mm)
Fe
:
0.6/0.8/0.9 SS: 0.6/0.8/0.9 Flux-Cored
:
0.8/0.9/1.0
Protection
class
IP23
Insulation
class
H
Dimensions
(
mm
)
465*214*395
465*214*395
Weight
(
Kg
)
12.5 Kg.
Note: The above parameters are subject to chan.
§3.2 Duty cycle and Over-temp
The rated duty cycle is defined as the proportion of the time that a machine can work continuously
over a 10 minute cycle when set at 100% of rated output welding current in 40C (104F) ambient
environment.
When the transformer reaches an over-heat condition, the heat sensor inside it will open and will
output an instruction to circuit board to cut AC relay and the output welding current while illuminating
the over-heat pilot lamp in the front panel. At this time, all welding operations should cease for 15
minutes allowing the cooling fan to reduce the temperature. The unit will auto-reset when correct
temperature has been achieved and pilot light will go out. If the machine reached the over-temp
capacity again, the welding output current or the arc cycle should be reduced.