2 screws
Attaching the Bracket to the Carriage
4. Using a dry wipe, clean the magnetic scale all along its complete length, as
shown below.
Magnetic Scale
Cleaning the Magnetic Scale
5. Disconnect the old encoder connectors.
6. Reinstall the B
RACKET
with the E
NCODER
R
EADER
, onto the C
ARRIAGE
but do
not tighten the screws yet.
7. Using the E
NCODER
R
EADER
's B
OX
B
RACKETS
, place the
ENCODER READER
's
electronic box over the right BCC card, and connect the new E
NCODER
R
EADER
connectors instead of the old connectors, as shown below.