Mastervolt chargemaster plus 12/100-3 Скачать руководство пользователя страница 1

 

 

 

 
 
 

 

CHARGEMASTER PLUS 

12/75-3, 12/100-3, 24/40-3, 24/60-3 

 

FULLY AUTOMATIC BATTERY CHARGER 

 

 

USER AND INSTALLATION MANUAL 

10000011898/13 

 
 
 

 

Содержание chargemaster plus 12/100-3

Страница 1: ...CHARGEMASTER PLUS 12 75 3 12 100 3 24 40 3 24 60 3 FULLY AUTOMATIC BATTERY CHARGER USER AND INSTALLATION MANUAL 10000011898 13...

Страница 2: ...lications 6 3 INSTALLATION 7 3 1 Unpacking 7 3 2 Environment 7 3 3 Wiring 7 3 4 Batteries 8 3 5 Things you need 8 3 6 Overview connection compartment 9 3 7 Connection example 10 3 8 Installation step...

Страница 3: ...overed by this warranty 1 4 Disclaimer Our products are subject to continual development and improvement Therefore additions or modifications to the products may cause changes to the technical data an...

Страница 4: ...ock disconnect the ChargeMaster Plus from both AC and DC electrical system before attempting any maintenance or cleaning Turning off controls will not reduce this risk Be sure that third parties canno...

Страница 5: ...E POS P battery post usually has larger diameter than NEGATIVE NEG N post 4 Determine which post of battery is grounded connected to the chassis If negative post is grounded to chassis as in most vehi...

Страница 6: ...tch determine voltage of battery by referring to car owner s manual and make sure it matches output rating of battery charger 2 10 Grounding instructions This battery charger should be connected to a...

Страница 7: ...g areas take into account that the fan of the ChargeMaster Plus can produce noise when operating Although the ChargeMaster Plus fully complies with all applicable EMC limits it may still cause harmful...

Страница 8: ...GND 120V 60Hz installations single phase Wire color Meaning Must be connected to Black Hot or Line L1 White Neutral N Green Ground PE GND 240V 60Hz installations split phase 120 240VAC Wire color Mean...

Страница 9: ...ge output 2 10 Temperature sensor connection 5 Positive terminal charge output 1 11 DIP switches 6 Screw terminals AC input 12 Ventilation openings Figure 2 Connection compartment Notes If the battery...

Страница 10: ...entire installation CAUTION Too thin cables and or loose connections can cause dangerous overheating of the cables and or terminals Therefore tighten all connections well in order to limit transition...

Страница 11: ...ening two screws at the lower side of the enclosure as well 4 Open the connection compartment by loosening the two screws 5 Connect the wiring to the screw terminals Fasten the cable with the cable cl...

Страница 12: ...occur caused by the capacitors used in the ChargeMaster Plus This is particularly dangerous in places with insufficient ventilation Due to the gassing of the batteries an explosion can occur Avoid ha...

Страница 13: ...ipment Event based commands With MasterBus a device can be programmed to initiate an action at another connected device This is done by means of event based commands 3 11 Decommissioning If it is nece...

Страница 14: ...MasterBus functions Adjustment of the settings of the ChargeMaster Plus can be made via the MasterBus network by means of an USB interface connected to a PC with MasterAdjust software Some settings c...

Страница 15: ...e chosen for feedback on the charged battery Not connected read only Output 2 Output 2 Output state Off pre float on read only Output 2 Voltage of charge output 2 read only Output 2 Output current of...

Страница 16: ...of this device English EN NL DE FR ES IT NO SV FI DA Name Name of this device This name will be recognized by all devices connected to the MasterBus CHG ChargeMaster 0 12 chars MB communication Selec...

Страница 17: ...ime the charger will start the Bulk stage 13 25 26 50V 0 15 50 0 31 00V Return to bulk Return to bulk delay time see Return to bulk voltage 30sec 0 240sec Alarm levels High alarm on Upper threshold le...

Страница 18: ...Event x 1 The next event appears after enabling Event x Disabled See Event x 4 2 10 Events source The ChargeMaster Plus can be configured as an event source An event source can be used to initiate an...

Страница 19: ...is available the ChargeMaster Plus will start to charge the batteries Note Once switched on the ChargeMaster Plus automatically resumes operation after it was disconnected from an AC source temporaril...

Страница 20: ...ium fast green Battery in bulk stage Blinking slow green Battery absorption stage Solid green Battery in float stage Battery III Blinking medium fast green Battery in bulk stage Blinking slow green Ba...

Страница 21: ...m the batteries can also remain connected to the ChargeMaster Plus during winter One hour every 14 days the charger automatically switches to absorption to keep the battery running properly and prolon...

Страница 22: ...charge a 24V starter battery or a 12V starter battery with its own charging profile Settings are configured via MasterBus see section 4 2 5 5 3 Starter alternator Outputs 1 and 2 are configured as ful...

Страница 23: ...ter Plus is required Examine your electrical installation on a regular basis at least once a year Defects such as loose connections burnt wiring etc must be corrected immediately If necessary use a so...

Страница 24: ...ed Check AC input voltage Batteries not fully charged Charge current too low See Charge current too low in this table Current to load is too high Reduce load taken from the batteries Charge time too s...

Страница 25: ...settings User defined AGM GEL Flooded AGM Spiral Flooded traction Flooded calcium MLI Li ion Dimensions mm 383 250 126 383 250 126 Dimensions inch 15 0 9 8 5 0 15 0 9 8 5 0 Weight 5 9 kg 13 lbs 5 9 kg...

Страница 26: ...User defined AGM GEL Flooded AGM Spiral Flooded traction Flooded calcium MLI Li ion Dimensions mm 383 250 126 383 250 126 Dimensions inch 15 0 9 8 5 0 15 0 9 8 5 0 Weight 5 9 kg 13 lbs 5 9 kg 13 lbs R...

Страница 27: ...75 3 12 100 3 24 40 3 24 60 3 User and Installation Manual 27 7 3 Dimensions Dimensions in mm inches ChargeMaster Plus models 12 75 3 12 100 3 24 40 3 and 24 60 3 7 4 3 Step charging characteristics...

Страница 28: ...rvolt com Location Shipping Power Products LLC N85 W12545 Westbrook Crossing Menomonee Falls Wisconsin 53051 United States Asia Pacific Customer Service T 64 9 415 7261 Option 1 E enquiries bepmarine...

Отзывы: