background image

STEP 3

Connect the air hose (1) to the compressor’s 
air outlet (2) with the quick connector (3).      
          page 13, step 5

STEP 4

Close the tank drain valve (1), located on the 
bottom of the air tank.           page 15, step 7

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

MC-589315-03

2

1

3

MC-589315-04

1

Содержание 058-9315-2

Страница 1: ...INSTRUCTION MANUAL 058 9315 2 5 U S GALLONS 18 9 L 135 PSI MAX AIR COMPRESSOR...

Страница 2: ...ction manual thoroughly before using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this p...

Страница 3: ...IR COMPRESSOR 058 9315 2 STEP 1 Set the pressure switch 1 to the OFF position page 14 step 1 STEP 2 Turn the air pressure regulator knob 1 counter clockwise until pressure drops down to zero on output...

Страница 4: ...to the compressor s air outlet 2 with the quick connector 3 page 13 step 5 STEP 4 Close the tank drain valve 1 located on the bottom of the air tank page 15 step 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 MC 5...

Страница 5: ...589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 589315 06 MC 5893...

Страница 6: ...589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 589315 07 MC 58931...

Страница 7: ...058 9315 2 QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 8 KEY PARTS DIAGRAM 9 IMPORTANT INFORMATION 10 12 ASSEMBLY INSTRUCTIONS 13 14 OPERATING INSTRUCTIONS 15 18 MAINTENANCE 19 21...

Страница 8: ...ed to standardized conditions of temperature and pressure RUNNING HORSEPOWER 1 5 TANK SIZE 5 U S gallons 18 9 L AIR DELIVERY CFM 40 PSI 4 8 AIR DELIVERY CFM 90 PSI 3 5 MAXIMUM PRESSURE PSI 135 PUMP DE...

Страница 9: ...e reader of something the user needs to know about the tool SAFETY RECOMMENDATIONS These precautions are intended for the personal safety of the user and others working with the user Failure to follow...

Страница 10: ...rs Risk of bursting Make sure the regulator is adjusted so that the compressor outlet pressure is set lower than the maximum operating pressure of the spray gun or tool Before starting the compressor...

Страница 11: ...bels when you are spraying paints or toxic materials and follow all safety instructions Use a respirator mask if there is a chance of inhaling anything you are spraying Also NEVER directly inhale the...

Страница 12: ...using an air compressor Failure to do so may result in hearing loss Do not carry the compressor while it is running Do not operate the compressor if it is not in a stable position Do not operate the c...

Страница 13: ...to 5 V at 150 of the rated amperes The smaller the gauge number of the wire the greater the capacity of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord When using...

Страница 14: ...5 2 No Description No Description 1 Tank pressure gauge 7 Air compressor pump 2 Air pressure regulator 8 Electric motor 3 Air outlet 9 Power cord 4 Outlet pressure gauge 10 Air tank 5 Pressure switch...

Страница 15: ...he air compressor being used can supply the appropriate volume pressure and delivery rate of air to the tool s without running continuously Using tools or combinations of tools that together or separa...

Страница 16: ...the valve Air pressure regulator The regulator is used to adjust the pressure inside the line to the tool that is being used Turn the knob clockwise to increase the pressure and counter clockwise to d...

Страница 17: ...Operates Tool Intermittently Not Recommended Finishing Nailer 16 gauge Framing Nailer Flooring Nailer Die Grinder Angle Grinder Air Ratchet Cut Off Tool DIY Paint Sprayer Brad Nailer 18 gauge 3 in 1...

Страница 18: ...rating for its intended use Packaging contents Positioning of the air compressor 1 Position the air compressor 1 near an electrical outlet 2 fig A 2 The compressor must be at least 12 31 cm from any w...

Страница 19: ...to the pump fig B Connect air hose to compressor 5 Connect the air hose 1 to the compressor s air outlet 2 with the quick connector 3 fig C Note Attach air hose and accessories not provided Apply plum...

Страница 20: ...d fig E 3 Turn the air pressure regulator knob 1 counter clockwise until it stops fig F 4 Plug in the power cord 1 fig G Note For best performance and reliable starting the air compressor should be pl...

Страница 21: ...will fill to cut out pressure and then the compressor s motor will stop The compressor is now ready for use CAUTION Potential hazard that may result in moderate injury or damage to equipment Use a ded...

Страница 22: ...pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating...

Страница 23: ...reduce the pressure in the tank fig M MC 589315 21 fig L 1 2 MC 589315 22 1 3 fig M 2 CAUTION Potential hazard that may result in moderate injury or damage to equipment Escaping air and moisture can...

Страница 24: ...ssure is minimized Place suitable container under unit to catch water Slightly tilt unit and turn drain valve counter clockwise to open After the water has been drained close the drain valve clockwise...

Страница 25: ...hnician WARNING Potential hazard that could result in serious injury or loss of life Be sure to wear protective goggles Relieve the air pressure in the system and open the drain valve on the bottom of...

Страница 26: ...over tighten any connections Storage Before storing the air compressor do the following Drain all moisture from the tank see Operating Instructions paragraph in the Maintenance section of this manual...

Страница 27: ...or has recovered 5 Replace the fuse or reset the circuit breaker Verify that the fuse has the proper amperage Check for low voltage conditions Disconnect any other electrical appliances from the circu...

Страница 28: ...lement 4 Decrease the amount of air used 5 Check the air hose and replace it if necessary 6 Replace the tank immediately Do not attempt to repair it 7 Check for worn parts and replace them if necessar...

Страница 29: ...EXPLODED VIEW 24 5 U S GALLONS 18 9 L 135 PSI MAX AIR COMPRESSOR 058 9315 2 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 2 22 1 22 22 3 23 24 25 26 27 28 29 30 31 33 32 MC 589315 23...

Страница 30: ...itch retainer 1 4 Frame Cap 4 22 Pump Motor assembly 1 5 Tank 1 22 1 Capacitor 50 f 1 6 Handle sleeve 1 22 2 Capacitor 200 f 1 7 Panel 1 22 3 Fan 1 8 Nut 4 23 Bolt M5x10 2 9 Bolt 7 24 Lock washer 2 10...

Страница 31: ...to fuel lubricants vacuum bags blades belts sandpaper bits fluids tune ups or adjustments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not a...

Страница 32: ...tions This warranty applies only to the original purchaser and may not be transferred Neither the retailer nor the manufacturer shall be liable for any other expense loss or damage including without l...

Отзывы: