1 Aspen Drive • Randolph, NJ 07869 • phone (973) 252-9119 • fax (973) 252-2455 • www.mastercool.com
98210 – B1 CALIBRATION PROCEDURE
1. Press
ON/OFF
then immediately press
CLEAR
+
TARE/ENTER
simultaneously
2. You will then see
SET-1
on the LCD
3. Press
TARE/ENTER
again
You will then see
SET-11
4. Press
TARE/ENTER
again
You will see
CAL
followed by a
5 digit number
5. Press
↓
(down arrow)
You will see “ZERO” appear on the bottom left side of the LCD momentarily
6. Place a known calibrated weight on the platform
The number on the LCD will change to a new 5 digit number
7. After the new five digits become stabilized, Press ↑ (UP arrow)
8. You will see the word “
TARE
” appear in the middle of the LCD for a moment
9. Press
TARE/ENTER
again and you will see
GOOD
10. Press
UNIT/SHIFT
and in combination with the ↑ and ↓ (UP/DOWN arrow keys) set the proper
display that corresponds to the exact weight that is placed on the platform
11. When you have completed setting the display in agreement with the actual weight press
TARE/ENTER
again and you will see
GOOD
followed by
HELLO
and the actual weight amount
will appear on the LCD again
12. Calibration is completed. Remove the weight from the platform and the scale should read 0.000
ELECTRONIC CHARGING SCALE
98210-B1-calibration