background image

1

SAFETY:

This user manual should not be used in place of common sense. Use this equipment in a  
manner that is specified with the vehicle manufacturer. Understand all the test procedures  
before attempting to use this equipment. Follow all safety precautions.
•  All diagnostic work should be performed with the engine off.
•  Do not leave the vehicle unattended when the equipment is connected or operating.
•  This equipment must be connected only to a fully charged 12VDC vehicle battery.

WARNING:

•  Do not use any other type of power source to run this equipment.
•  Do not use this equipment near a source of spark or ignition.
•  Always use this equipment in a well-ventilated area.
•  Always wear eye protection and gloves when using this equipment. 

SPECIFICATIONS:

•  Voltage: 12 VDC
•  Input Pressure: Max 100 psi (8.2 bar)
•  Output Pressure: 12 – 14 inH2O (30 – 35 mBar)
•  Safety Pressure Relief: 120 (±5) psi
•  Auto Shut-off: 5 minutes
•  Oil Fill Line Indicator: 3.4 oz (100 ml (±10 ml)
•  Flow Meter: 0 - 0.040 in. (0 - 1.0 mm) 
•  Weight: 11.9 lbs (5.4 Kg) 

•  Power Consumption: Max 6.5 Amps
•  Operating Temperature: 0 °F to 140°F (-17°C to 60°C )
•  Operating Humidity: No Restrictions
•  Operating Altitude: No Restrictions
•  Vapor Output Hose: 10 feet
•  Power Cable: 10 feet
•  Pressure Supply: Air/Inert gas/Pump
•  Dimensions: 11.8 x 8.1 x 11 in (300 x 205 x 280 mm)

INCLUDED ACCESSORIES:

1.  Full set of block off caps
2.  Exhaust cone
3.  Evap schrader valve remover/installer

4.  Evap service port adapter hose (green cap)
5.  High intensity smoke illuminating battery powered flashlight
6.  8 oz smoke producing fluid

MACHINE COMPONENTS:

1.  Smoke vapor switch
2.  Internal pump switch
3.  Smoke indicator light
4.  Power source light
5.  Internal pump indicator light
6.  Compound pressure gauge

7.  Flow meter with control knob
8.  Oil fill
9.  Smoke hose fitting & smoke hose cap fitting
10. Shop air/inert gas inlet
11. Maximum oil level
12. 12 VDC power cord connection

6

5

4

3

2

1

EVAP DIAGNOSTIC SMOKE MACHINE INSTRUCTIONS

1

2

3

5

4

6

7

8

9

10

11

12

Отзывы: