Dear customer, thank you for purchasing a MASTER product. This manual describe the operations for a correct installation of the product. This device is not design for a continuative
use. Use of the product other than that provided for in this manual is improper and prohibited and will void the warranty and any manufacturer's liability. The installation of the product
must be done by a qualified technician. At the end of the installation, all manuals must be given to the end user. Keep this manual for future reference!

The technical characteristics of the motor are shown in the label applied to the motor tube. The common characteristics of the motor family are:

Power supply

: 230 Vac 50 Hz

Stand-by comsuption

: < 1W

Minimum roller diameter

: 50 x 1.5 mm

IP insulation

: Ip44

Insulation class

: H

Continuos operating time

: 4 minutes

Operating radio frequency

: 433.42 MHz

N° of memorizable transmitter

: 40

01. TECHNICAL SPECIFICATIONS

02. WARNINGS

PRODUCT INFORMATION

Incorrect installation can cause serious injuries

Keep these instructions for future maintenance work and disposal of the product

All the product installation, connection,

programming and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws, provisions, local regulations and the instructions
given in this manual

The wiring must comply with current IEC standards. The final electrical system must be created only by the electrician

Some applications require hold-to-run

operation and can exclude the use of radio controls or require particular safety devices

To prevent potentially dangerous situations, check the operating condition of the roller

shutter/awning regularly

02.1 Warnings for safety

Before installing the product, check the compatibility with the associated devices and accessories

Check that the package is intact and has not been damaged in transit

A heavy

knock and the use of unsuitable tools can cause the damage of the external or internal parts of the motor

Do not pierce or tamper with the motor in any way. Do not modify or replace

parts without the manufacturer's permission

Do not carry the motor by the power cable. The product may not be used if the power cable is damaged. Do not try to replace the power

cable

Any screws needed to complete the installation must not come into contact with the motor

The power of the motor must be sufficient for the applied load (check the rated data

shown on the motor)

Some stages of programming and/or normal operation make use of the mechanical stops of the roller shutter/awning. It is essential to choose a motor with the

most suitable torque for the application, considering the actual traction of the roller shutter/awning, and to avoid motors that are too powerful

Use winding rollers that are at least

1mm thick

Leave 1-2 mm of right/left play on the winding roller

Check that the shape and size of the drive pulley and adapter crown correspond to the winding roller used. Adapters,

supports and sundry accessories related to the motor must be chosen exclusively from the MASTER catalogue

If the product is installed at a height of less than 2.5 m from the floor

or from another support surface, the moving parts must be protected with a cover to prevent accidental access. In any case, ensure access for maintenance work

The power cable

must be positioned in such a way that it does not come into contact with moving parts

The power cable of the product is suitable for indoor installation only. If installed outside, place

the cable in a protective tube

Position the buttons within sight of the roller shutter/awning but a long way from its moving parts. Position the buttons more than 1.5 m from the floor

The motors are designed for residential use; the maximum continuous operating time is 4 minutes

During operation, the motor body becomes very hot, so be careful

The motor

contains a self-resetting thermal cut-out, which stops the motor if it overheats. The motor returns to normal operation when its temperature drops below the safety limit (normally after 5
to 10 minutes)

The motor must be installed so that it cannot come into contact with liquids and in any case in a position protected from atmospheric agents

For your safety, do not

work near the winding roller while the motor is powered

Where possible program the upper limit of the motor by contact with an obstacle. This solution will allow the motor to

automatically recalibrate the limit switches recovering slight deviations due to adjustment of the roller or a continuous and sudden power loss

If there are several radio appliances in

the same system, they must not be less than 1,5m apart

Do not install the product near metal surfaces

The product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are
supervised or given instructions about the product way of use by a person responsible for their safety

Check the automation during the movement and keep people at a safe

distance, until the movement ends

Do not allow children to play with the appliance or with the fixed control devices

Do not operate the blind when maintanance operations are

being carried out (e.g. window cleaning, etc.). If the control device is automatic, disconnect the motor from the power line

02.2 Warnings for installation

02.3 Warnings for use

01

USER MANUAL

tubular motor Ø45 mm with electronic limit switch

R

rev01_1  20.05.2019

MODO

MODO has been designed to drive drop awning, specially for structures where there are manual or automatic hooks placed near the lower
limit switch.
The motor is equipped with systems for recognizing any obstacles during the down phases (only if a offset adapter has been correctly
installed, see section "03 INSTALLING THE OFFSET ADAPTERS"). If the drop awning is equipped with cassette and the motor is equipped
with a offset adapter, during the installation the product is able to automatically detect and memorize the limit switches. Moreover, the
presence of the cassette will allow the motor to independently recover any deviations from the limit switches due to adjustment of the drop
awning or other possible error factors; it is therefore recommended to always install the drop awning with cassette.
If you proceed with the installation in the absence of the cassette, it may occasionally be necessary to adjust the limit switches.
If the drop awning is not installed properly, the motor may detect non-existent obstacles during the up or down movements. In this case it is
necessary to verify the installation.

Information for any assistance requests

To facilitate, improve and speed up any request to the assistance service it is necessary to provide the product name to the operator.

Before installing the motor, it is recommended to copy the technical data (including the extended product name) and store them in a safe place

It is advisable

(for example, near police stations, airports, ports, hospital, etc). A technical inspection is in any case advisable before installing

any radio system in order to identify sources of interference. Radio systems can be used where possible disturbances or malfunctioning of the transmitter or the receiver do not cause a risk factor, or if the risk factor
is cancelled by suitable safety systems. The presence of radio device operating on the same transmission frequency (

) can interfere with the radio receiver of the motor and so reduce the range of the

system and limit the functionality of the installation.

to avoid using radio systems in areas with strong interference

433,42 MHz

Notes on radio systems

MASTER uses packaging recyclable materials. Dispose materials on the proper containers, complying with the law in force in your locality.
This product may have substances that are polluting for the environment and dangerous for the health.
At the end of the product life cycle, carefully comply with the waste disposal rules. It is strictly forbidden to dispose the product on the domestic waste.

Disposal

Содержание MODO

Страница 1: ...MODO rev 01 1_20 05 2019 Seleziona la lingua Select the language...

Страница 2: ...ionamento quando la sua temperatura scende sotto il limite di sicurezza normalmente da 5 a 10 minuti Il motore deve essere installato in modo tale da non venire a contatto con liquidi e comunque in po...

Страница 3: ...i I pulsanti di comando opzionali devono essere applicati ai fili NERO e GRIGIO e devono chiudere sul filo MARRONE fase Devono essere utilizzati pulsanti a posizioni momentanee a uomo presente non uti...

Страница 4: ...devono essere installati in prossimit del finecorsa inferiore Per ganci automatici si intendono dei sistemi di aggancio sgancio che funzionano in modalit passo passo Se durante la salita il motore inc...

Страница 5: ...regolare con pi precisione la posizione vedi il box Regolazione fine dei finecorsa altrimenti attendi circa 10 secondi 8 Il motore si muove in salita Se l installazione prevede una battuta superiore...

Страница 6: ...lita Se l installazione prevede una battuta superiore consigliato vai al punto 9 altrimenti vai al punto 10 9 Finecorsa superiore per pressione opzione consigliata attendi che il terminale si appoggi...

Страница 7: ...e consigliato vai al punto 9 altrimenti vai al punto 10 9 Finecorsa superiore per pressione opzione consigliata attendi che il terminale si appoggi alla battuta Il motore effettua un breve movimento i...

Страница 8: ...gliato vai al punto 9 altrimenti vai al punto 10 9 Finecorsa superiore per pressione opzione consigliata attendi che il terminale si appoggi alla battuta Il motore effettua un breve movimento in disce...

Страница 9: ...cancellato 2 movimenti gi errore PROG 5 secondi NOTE punto 03 nei sensori a batteria pu essere necessario mantenere il pulsante premuto fino a 10 secondi punto 04 viene segnalato errore se il codice...

Страница 10: ...la comunicazione radio La fabbrica consiglia di mantenere attivo il test radio al fine di individuare in tempo utile eventuali malfunzionamenti del sensore radio Per modificare questo parametro La pre...

Страница 11: ...possibile decidere se il motore deve sempre raggiungere la battuta impostazione 1 autozero senza rilascio se il motore deve sempre raggiungere la battuta e rilasciare brevemente il telo impostazione...

Страница 12: ...ch stops the motor if it overheats The motor returns to normal operation when its temperature drops below the safety limit normally after 5 to 10 minutes The motor must be installed so that it cannot...

Страница 13: ...pplied to the tube of the motor 04 3 Command buttons optional The command buttons must be connected to the black and gray wires and they must close on brown wire do not use buttons with maintained pos...

Страница 14: ...a between the upper end stop and approximately 30 cm above the hooks 05 2 MANUAL HOOKS MODE The hooks must be installed near the lower limit switch Automatic hooks means hook and release systems that...

Страница 15: ...ly STOP FIRST MOVEMENT The motor moves downward 7 The motor stops automatically when terminal bar reaches the lower limit otherwise press STOP to stop the motor in the desired position if mount with o...

Страница 16: ...bar reaches the lower limit otherwise press STOP to stop the motor in the desired position if mount with offset adapter If you want to adjust the position more precisely see the Fine adjustment of the...

Страница 17: ...ward 7 The motor stops automatically when terminal bar reaches the lower limit otherwise press STOP to stop the motor in the desired position if mount with offset adapter If you want to adjust the pos...

Страница 18: ...7 The motor stops automatically when terminal bar reaches the lower limit otherwise press STOP to stop the motor in the desired position if mount with offset adapter If you want to adjust the position...

Страница 19: ...DELETE A RADIO DEVICE 01 Bring the motor in an intermediate position 02 Press PROG of an already memorized transmitter for 5 s The motor performs 2 upward movements 03 Within 15 seconds to memorize d...

Страница 20: ...5 To select PULSE press PREV To select HOLD TO RUN press NEXT 06 Press STOP The motor signals see table 01 Bring the motor in an intermediate position 02 Holding down STOP press PROG for about 1 sec u...

Страница 21: ...ing 1 to 4 06 Press STOP The motor signals the new value 1 to 4 movements See the User manual of the transmitter at section RECEIVER MENU Function 13 factory setting factory setting N of movements Set...