Страница 1: ...MASTER SPAS 2003 MODEL YEAR THE LEGEND SERIES THE LEGEND SERIES INSIDER THE LEGEND SERIES XTREME The ultimate relaxation machine...

Страница 2: ...P NAME ADDRESS CITY STATE ZIP DATE PURCHASED MODEL SERIAL DEALER NAME DEALER ADDRESS DEALER PHONE SERVICE TECH REPRESENTATIVE COMMENTS Manufactured by MASTER SPAS 6927 Lincoln Parkway Fort Wayne IN 46...

Страница 3: ...1i 3 4 Stage ECO PUR Filtration System Insert 4 Spa Operating Procedures THE LEGEND SERIES 12 13 THE LEGEND SERIES INSIDER 14 15 Setting the Ti1ne 16 Option Filter Cycle Progranuning 17 18 Periodic Re...

Страница 4: ...Please take time to point out the physical location of the safety sign and the importance of the safety precautions displayed on the safety sign to all of your guests Remember your safety and the saf...

Страница 5: ...al water pipe or conduit within 5 feet 1 5M of the unit 4 DANGER RISK OF ELECTRIC SHOCK Install spa at least five 5 feet 1 5M from all metal surfaces A spa may be installed within five 5 feet 1 5M of...

Страница 6: ...THE EFFECTS OF HYPERTHERMIA INCLUDE Unawareness of Impending Hazard Failure to Perceive Heat Failure to Recognize the Need to Exit Spa Physical Inability to Exit Spa Fetal Damage in Pregnant Women Un...

Страница 7: ...ny electrical installation A copper bonding lug has been provided on the electlical equipment pack to allow co1mection to local ground points The ground wire must be at least 6 AWG copper wire and mus...

Страница 8: ...Wiring Schematic House Breaker Box G F C I Breaker Box z g c ________ Fronl l iell ofG FC I Square DJ I I 7 Bollom l il r u_ G FC I Square DJ TBI IIITE t ElTR L 2F Blh tllOTl 3 c __ __r till I IIOT r...

Страница 9: ...nforcement bars crossed throughout the pad IMPORTANT When installing your spa indoors or on a wood deck or balcony the same load requirements must be met Total load may be as much as 75 pounds per squ...

Страница 10: ...may begin This is the fun part CAUTION DO NOT APPLY POWER TO OR OPERATE THE SPA WHEN THE SPA IS PARTIALLY FILLED OR THERE IS NO WATER IN THE SPA 1 Be sure that the circuit breaker in you breaker panel...

Страница 11: ...ture pumps the spa light automatic filtration cycles and other advanced functions The digital display will give you a constant temperature readout and will notify you in case of certain malfunctions S...

Страница 12: ...et action The main pump is controlled by the Therapy I button on the Topside Control Panel or by using the Personal Remote Control next to the Aqua Pressure Seat LS Series only 21 SECONDARY PUMP This...

Страница 13: ...Blaster r ide Control Panel I I 11 Equipment Access I I1 Neek Jets I I7 Air Control Valve I I2 Shoulde Jet j i 7 A ir _C_ o nt r ol _V _ a_ lv_ e_ 6 Cascade Waterfall Diverter Valve Remote Control I11...

Страница 14: ...1 N I 12 Access Panel I I 14 Weir Gate I I13 Filter Lid 1 Ci I7 Air Control Valve I I 7 Air Control I I9 Topside Control PaneCj 7 Air Control Valve SS for Master Blaster LS and 115 Spa Light j r e i...

Страница 15: ...Control Panel I 7 Air Control Valve for Master I25 Ozonator I Equipment placement may vary by model 26 Spa Light I7 Air Control I I M S 1 ER SPAS 17 Equipment I LI 24 Heater Union I Control System 0...

Страница 16: ...e filter area With the use of set pins held in place simply tun1 the pins a quaiter tum in either direction and lift the element out for cleaning The next stage use 2 micro or fine filter elements sim...

Страница 17: ...Waim or Cool button once to display theset temperature Each time either button is pressed again the set temperature will increase or decrease depending on which button is pressed After three seconds t...

Страница 18: ...er the last setting The default filter cycles are as follows The first filter cycle is automatically activated at 8 00 AM and lasts until 10 00 AM The second filter cycle is automatically activated at...

Страница 19: ...me either button is pressed again the set temperature will increase or decrease depending on which button is pressed After tlrree seconds the LCD will automatically display the last measured spa tempe...

Страница 20: ...ns tempora1ily This is helpful when changing a filter Pressing any button resets the spa Preset Filter Cycles There are two filter cycles per day The staii end times of each cycle are progranmrnble To...

Страница 21: ...TIME PROGRAM Then 8 Or 8 WARM COOL After either pad is pressed once hours will increase or decrease automatically in one minute increments Press either pad again to stop the display s time setting cyc...

Страница 22: ...SET FILTER 1 AM cycle along with flashing START TIME icon will appear on the display r fl DG fl A 111 Press B 8 PROGRAM or to reset the filter start time WARM COOL Press 111a G11 1 to see SET FILTER...

Страница 23: ...FILTER 2 along with flashing PROGRAM END TIME icon and adjust the time with the s WARM or 8 as done above COOL fll7DGR I H Pressing 5 will enter the new filter cycle times into PROGRAM the system and...

Страница 24: ...heater Overheat The spa has shut down of the sensors has detected that the spa water is 110 F Ice Potential freeze condition detected Spa is shut down The sensor that is plugged into the Sensor A jack...

Страница 25: ...has been activated by pressing a button combination on user panel 20 Ifthe problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear wh...

Страница 26: ...pl servic of Lhis conlml system Contact your dealer or sen ice organuation for assistance Follow all a rner s manual po r connection instructions lnstallation must oo performed by a licensed electrici...

Страница 27: ...with any questions TO CLEAN YOUR FILTER ELEMENTS The filter in your spa is one of the most important components of your spa It not only is essential for clean water but also for extending the life of...

Страница 28: ...in sealer to maintain its appearance and to preserve its life Several times a year especially iflocated outdoors it is reconm1ended that your cabinet be re treated Your local dealer or service center...

Страница 29: ...use an inexpensive submersible pump that you can buy from your dealer or your local hardware store 2 Use a shop vac to get all standing water out of your unit 3 Remove access panels from equipment are...

Страница 30: ...YOUR DEALER IS ESSENTIAL FOR PROPER WATER CARE ALSO CHANGING YOUR WATER ON A REGULAR BASIS IS A VERY INEXPENSIVE CHEMICAL TREATMENT ADDITIONAL INFORMATION I RECOMMENDATIONS CHEMICAL ADDITIVE BENCHMARK...

Страница 31: ...250 PPM can promote scale fonnation making deposits in the spa and reducing your heaters efficiency Water that is too low in calcium hardness may also be hannful Soft water under 180 PPM will more rap...

Страница 32: ...ler c Check for correct wiring a Be sure temperature is set to the desired temperature b Be sure adequate time has been allowed for heating c Refer to heater control instructions a Be sure filter is c...

Страница 33: ...age to add a small amount of chlorine to oxidize organic compounds ECO PUR will not eliminate the need to maintain proper water chemistry but can make the maintenance a more natural experience TM Mast...

Страница 34: ...hould be 7 2 7 8 and the total Alkalinity 80 150 PPM Calcium hardness levels should be maintained between 150 and 250 PPM part per million Adjust pH total Alkalinity and Calcium hardness utilizing the...

Страница 35: ...chlorine to assist in sanitization and oxidation processes required to maintain clear spa water ECO PUR water purification will not alter the pH of spa water The mineral combination will actually aid...

Страница 36: ...ements overnight in a bucket with spa Filter Cleaner and then rinse with clean water before re inserting The ECO PUR mineral element should never be cleaned in a filter cleaner Just rinse with water E...

Страница 37: ...t J MASTER SPAS INC 6927 Lincoln Parkway Fort Wayne IN 46804 260 436 9100 www masterspas com lauter masterspas com...