background image

O W N E R ’ S   M A N U A L

Master Spa Parts

Call Us Today : (920) 727 - 1700

Master Spa Parts - 1068 American Drive, Neenah, WI, 54956, USA

Содержание Twilight Series

Страница 1: ...O W N E R S M A N U A L Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 2: ...______________________________________ Address ____________________________________________________________________ City _____________________________________ State __________ Zip ______________ Date...

Страница 3: ...ouble Shooting Guide 23 Why Chemicals are Important in a Spa 24 Maintenance Recommendations 25 Winterizing Your Spa 26 Twilight Spa Specifications 27 Twilight Spa TS 6 1 TS 6 2 TS 7 1 TS 8 1 Controls...

Страница 4: ...permanent fastener Additional or replacement signs can be obtained from your dealer or direct from the factory INTRODUCTION It s time to relax You now have your very own portable spa by Master Spas In...

Страница 5: ...f in accordance with the National Electrical Code each metal surface is permanently connected by a minimum No 6 AWG 8 4mm solid copper conductor attached to the wire connector on the terminal box A gr...

Страница 6: ...culatory system problems should consult a physician before using the spa F Since excessive water temperatures have a high potential for causing fetal damage during early months of pregnancy pregnant o...

Страница 7: ...d temperatures above 99 F Children should spend less time in water above body temperature than adults 8 WARNING The use of alcohol drugs or medication can greatly increase the risk of hyperthermia J T...

Страница 8: ...o components etc to the system These units are not provided with an outdoor antennae Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other haz...

Страница 9: ...ment 16 At least two lugs marked Bonding Lugs are provided on the external surface or on the inside of the supply terminal box or compartment To reduce the risk of electric shock connect the local com...

Страница 10: ...ATTEINTES DE MALADIES INFECTIEUSES NE DEVRAIENT PAS UTILISER UNE CUVE DE RELAXATION WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB AVERTISSEMENT POUR VITER DES BLESS...

Страница 11: ...DE RELAXATION CAUTION MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH MANUFACTURER S INSTRUCTION ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT Hyperther...

Страница 12: ...s produces water flow through the designated jets and has only one speed 4 JETS 3 PUMP If so equipped This produces water flow though the designated jets and has one speed 5 CIRCULATION PUMP If so equ...

Страница 13: ...trical supply for your spa must include a 50 AMP switch or circuit breaker to open all non grounded supply conductors to comply with section 422 20 of the National Electrical Code The disconnect must...

Страница 14: ...e is not required between the G F C I and the system box GRN GRN GROUND RED HOT BLK HOT BLK HOT RED HOT RED HOT WHT NEUTRAL WHT WHT BLK HOT GRN GROUND TB1 IDF00007 mac 6 17 97 Actual wiring of GFCI wi...

Страница 15: ...that the base beneath the spa can support the actual weight The spa must be on a uniformly firm continuous and level surface The recommended foundation is a concrete pad with a minimum thickness of fo...

Страница 16: ...codes if applicable Power cable GENERAL CONSIDERATIONS FOR INDOOR INSTALLATION Installing your spa indoors creates an entirely different set of considerations Here again with proper planning no matte...

Страница 17: ...start up your spa pumps do not operate Due to the nature of water flow and hydro therapy pumps please be advised that air locking of pumps may occur Master Spas has taken measures to reduce the possi...

Страница 18: ...the lower the pH pH is not measured in parts per million but on a scale from 0 to 14 with 7 being the neutral In spas when ever possible a measurement between 7 2 and 7 8 is best Whenever possible it...

Страница 19: ...is a granule fast dissolving and pH neutral 2 Chlorine is an immediate sanitizer B Bromine 1 Two types of tablets a Hydrotech b Lonza 2 Bromine is a slow dissolve chemical and may take a few days to...

Страница 20: ...ock treat with 1 teaspoon of Dichlor per 500 gallons These are general recommendations for water quality maintenance that may vary by usage and or bather load Depending on bather load and frequency of...

Страница 21: ...ecessary to within the 7 2 and 7 8 range using the pH alkalinity increaser or decreaser 1 2oz at a time Wait 15 minutes retest and adjust if necessary The pump should be running on high speed during t...

Страница 22: ...the label directions 5 Use a small amount of defoamer only if necessary DAY TWO SKIP DAY THREE 1 Test and adjust total alkalinity if necessary to between 80 and 150 ppm using the pH alkalinity increa...

Страница 23: ...r superchlorinate following label directions A spa should be shocked at least once a week even if it is not used If using chlorine as the sanitizer the spa should be shocked whenever a free chlorine r...

Страница 24: ...ls lotions soap etc HOW TO FIX IT Shock water with non chlorine shock treatment Adjust pH if necessary Shock water with non chlorine shock treatment or adjust sanitizer levels Adjust pH level if neces...

Страница 25: ...ronment surrounding the spa is also a consideration Watch for pollen grass sand dirt lawn fertilizer dust storms insects dogs cats etc 5 Consider the human next In a heated spa the average adult sweat...

Страница 26: ...spa is one of the most important components of your spa It not only is essential for clean water but also for extending the life of the spa equipment Your filter element must be cleaned regularly once...

Страница 27: ...rom equipment area 4 Loosen all pump unions 5 Remove winterizing plug from the face of the pump s 6 Using your shop vac in a blowing mode insert the hose into the nozzle of each jet and blow the trapp...

Страница 28: ...84 x 84 x 38 240V 420 705 1 28 50 Amp 3 995 TS 7 2 84 x 84 x 38 240V 420 755 2 36 50 Amp 4 045 TS 8 1 94 x 94 x 38 240V 485 750 1 29 50 Amp 4 630 TS 8 2 94 x 94 x 38 240V 485 755 2 44 50 Amp 4 680 TS...

Страница 29: ...splay the set temperature press the Temp pad once To change the set temperature press the pad a second time before the LCD stops flashing Each press of the Temp pad will continue to either raise or lo...

Страница 30: ...the set temperature only during filter cycles will display solid when temperature is not current and will alternate with temperature when temperature is current Preset Filter Cycles The first filter...

Страница 31: ...omatically activate regardless of spa status If the problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools If...

Страница 32: ...Sensors are out of balance If alternating with spa temperature it may just be a temporary condition If flashing by itself spa is shut down A significant difference between temperature sensors has been...

Страница 33: ...spas equipped with 24 hour circulation pump To display the set temperature press the Warm or Cool pad once To change the set temperature press the pad a second time before the LCD stops flashing Each...

Страница 34: ...temperature is not current and will alternate with temperature when temperature is current Preset Filter Cycles The first filter cycle begins 6 minutes after the spa is energized The second filter cy...

Страница 35: ...persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools If the problem persists contact your dealer or service organiza...

Страница 36: ...e it may just be a temporary condition If flashing by itself spa is shut down A significant difference between temperature sensors has been detected This could indicate a flow problem Persistent low f...

Страница 37: ...grades The wireless remote provided with the spa is water resistant but should never be left in the spa when not in use RF Remote Control Synchronizing Each docking station comes with a matching wirel...

Страница 38: ...o not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury Refer all servicing to qualified service personnel NOTE When the power sup...

Страница 39: ...OPERATE 1 Press the Jets button on your control panel If you hear the pumps trying to operate A Pump may need to be primed See page 16 If you do not hear anything from the pump contact your local ser...

Страница 40: ...e spa should be heating Wait a reasonable amount of time approximately 1 hour to see if the water temperature is changing 6 Check to make sure that the pump is primed 7 Reset power to the spa at GFCI...

Страница 41: ...ng on model TO CLEAN JETS Place the jet s in a bucket fully immerse in white vinegar Let the jet s soak overnight and then rinse with water Reinstall the jet s It may also be necessary to clean the gr...

Страница 42: ...ONGED PERIODS DO NOT REPLACE COVER DIRECTLY ON SURFACE OF SPA PLACE 2 3 BLOCKS BETWEEN COVER AND SPA THIS ALLOWS FOR ADEQUATE VENTILATION OF COVER AND SPA NOTE The cover warranty is provided through t...

Страница 43: ...er Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Spa Cover Miscellaneous Service Miscellaneous Service DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920...

Страница 44: ...SPA CARE AND MAINTENANCE RECORD 43 DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 45: ...SPA CARE AND MAINTENANCE RECORD 44 DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 46: ...Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 47: ...ind every product we produce pursuant to those representations which are stated in our written limited warranty your dealer is an independent business person or company and not an employee or agent of...

Отзывы: