Mastech MS20006 Скачать руководство пользователя страница 1

MS2000G

DIGITAL AC/DC CLAMP METER

MASTECH

HOLD

SAFETY INFORMATION  .……………………………2

SAFETY SYMBOLS   .…………………………………2

SAFETY PRECAUTIONS  ……………………………3

MAINTENANCE .………………………………………4

GENERAL DESCRIPTION  …..………………………4

FRONT PANEL DESCRIPTION …..…………………5

OPERATING INSTRUCTIONS ………………………8

SPECIFICATIONS     …...……………………………11

REPLACING THE BATTERY   ...……………………12

ACCESSORIES ………………………………………13

CONTENTS

Содержание MS20006

Страница 1: ...ETER MASTECH HOLD SAFETY INFORMATION 2 SAFETY SYMBOLS 2 SAFETY PRECAUTIONS 3 MAINTENANCE 4 GENERAL DESCRIPTION 4 FRONT PANEL DESCRIPTION 5 OPERATING INSTRUCTIONS 8 SPECIFICATIONS 11 REPLACING THE BATTERY 12 ACCESSORIES 13 CONTENTS ...

Страница 2: ...ate precautions to avoid misleading Follow all safety and operating instructions to ensure maximum personal safety during the operation and to ensure the meter is used safely and is kept in good operating condition Read these operating instructions thoroughly and completely before operating your meter Pay particular attention to WARNINGS which will inform you of potentially dangerous procedures Th...

Страница 3: ...trained and another person capable of rendering first aid and resuscitation is present MAINTENANCE The meter is a handheld 31 2 digital clamp meter for GENERAL DESCRIPTION measuring DC and AC voltage AC current Resistance Frequency Temperature C F Diode and Continuity Test with battery operated Transformer jaws Pick up the AC current flowing through the conductor Hold button When this button is pu...

Страница 4: ...inal for ohms Connection is made to it using the red test lead Temperature Measuring Socket Insert a K type thermocouple into the temperature measuring socket and contact the object to be measured with the thermocouple probe Trigger Press the lever to open the transformer When the lever is released the jaws will close again 7 8 9 10 MASTECH HOLD 06 CLAMP METER LAYOUT 1 2 3 4 5 6 8 9 10 7 ...

Страница 5: ...ent value on LCD display RESISTANCE MEASUREMENT 1 Connect the red test lead to Ω jack and black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at desired Ω range position 3 Connect test leads across the resistor to be measured and read LCD display 4 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before ...

Страница 6: ...input 2 In noisy environment it is preferable to use shield cable for measuring small signal DIODE TEST 1 Connect the red test lead to Ω jack and the black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at position 3 Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode 4 The approx forward volta...

Страница 7: ...00V 1000V Resolution 1mV 10mV 0 1V 1V Accuracy 0 5 of rdg 1 digit 1 0 of rdg 2 digit Input Impedance 10MΩ AC VOLTAGE Range 200V 750V Resolution 0 1V 1V Accuracy 1 0 of rdg 3 digit Input Impedance 10MΩ Frequency range 40Hz to 400Hz Response Average responding calibrated in rms of sine wave AC CURRENT Range 200A 2000A Resolution 0 1A 1A Accuracy 2 0 of rdg 5 digit Overload Protection 2200A for 60 se...

Страница 8: ...y should be replaced Use the following procedure to replacing the battery 1 Disconnect test leads from any live source turn the rotary switch to OFF and remove the test leads from the input terminals 2 The battery cover is secured to the bottom case by a screw Using a screwdriver remove the screw from the battery cover and remove the battery cover 3 Remove battery and replace with a new equivalent...