Masser EXCALIPER HC Скачать руководство пользователя страница 8

 

 

 

 

3.3 SEALS 

 
Masser calipers are designed to withstand moisture and water. All devices are tested 
pressurized under the water before delivery. To maintain the waterproofness user 
should check periodically that the seals are not damaged in use. 
 
ENTER 

– button has a rubber boot which can be changed by the user. (Spare part 

no: 13798 Rubber Boot, including a special key for removing the old boot and fixing 
the new). Check the boot periodically for the small incisions so that there is no cut 
growth. If the seal fails the ENTER button can get moisture and impurities inside. 
 
If you find any moisture inside the display, take the calliper in a dry place and open 
the nine Allen screws holding the cover. Let the calliper dry and assemble the cover 
carefully back. If you do not find the reason for the leak, contact the nearest service 
point. 

3.4 CLEANING, LUBRICATING 

 
Use only by mild soap moistened cloth to clean the caliper. Try to get resins off 
mechanically. 
The bearings in slide rollers are pre-lubricated and do not need any service. 
 

Do not use any kind of solvents or oil !!! 
 

3.5 STORING 

 
Do not leave the caliper in a closed car on direct sunshine. The temperature can rise 
easily over 50ºC and this temperature is critical for the batteries and for some 
components. 
 

3.6 MAGNETIC SCALE

 

 

Masser Excaliper-models are equipped with a magnetic diameter measuring sensor. 
The magnetic measuring principle is accurate and gives reliable readings regardless 
of temperature variations and humidity (rain) and needs minimum amount of energy 
for operation.  
 
Even though the magnetic scale is sturdy, it is recommended that the caliper is not 
used or stored next to magnetic equipment. (electric motors, big solenoids, monitors 

Содержание EXCALIPER HC

Страница 1: ...Masser Oy Tel 358 400 904 500 BID No 0665142 9 Norvatie 4 masser masser fi VAT No FI06651429 FI 96910 Rovaniemi Finland www masser fi Domicile Rovaniemi MASSER EXCALIPER HC USER MANUAL V1 0...

Страница 2: ...ETER 4 2 3 CALIBRATING THE CALIPER 4 2 4 CONNECTIONS 5 2 5 DOCKING STATION 6 3 MAINTENANCE 7 3 1 MAIN BATTERIES 7 3 2 MEMORY BACK UP BATTERY 7 3 3 SEALS 8 3 4 CLEANING LUBRICATING 8 3 5 STORING 8 3 6...

Страница 3: ...HC computer caliper to be used with a tailored software package separate software manual 2 DEVICE 1 movable arm 2 fixed arm 3 TOGGLE switch 4 display 5 communication port docking station 6 slide 7 se...

Страница 4: ...rger than set in SETTINGS menu buzzer gives a warning beep User should then measure the diameter by tape and feed this value in mm by TOGGLE switch or by typing from the keyboard this feature can be d...

Страница 5: ...CTIONS The cable set delivered with the caliper can be connected directly from docking station to PC s serial port One end of the cable must be connected to 12 VDC fuse box and protected with max 4A f...

Страница 6: ...king station according to following picture 1 Insert the caliper slide to upper holder 2 Install the caliper to docking station by pressing the caliper gently 3 Remove the caliper from docking station...

Страница 7: ...arge for longer since the battery s charge control ensures that the battery is not overcharged The caliper detects when the harvester is switched off and then turns itself off automatic power off afte...

Страница 8: ...ack If you do not find the reason for the leak contact the nearest service point 3 4 CLEANING LUBRICATING Use only by mild soap moistened cloth to clean the caliper Try to get resins off mechanically...

Страница 9: ...the caliper with ENTER the caliper shows RUN PROG INSTALL MEM TEST SHUT DOWN RUN PROG starts the program form the main menu INSTALL the caliper starts to wait a new program from PC On the display is a...

Страница 10: ...This Masser software is licensed and not sold Masser Oy warrants that this Masser product will substantially conform to Masser s applicable published specifications for the software for a period for n...

Страница 11: ...11 6 CONTACT INFORMATION MASSER OY Norvatie 4 FI 96910 ROVANIEMI FINLAND Tel 358 400 904 500 Fax 358 16 282 554 e mail masser masser fi www masser fi...

Отзывы: