wood fires.
A
B
E
F
G
H
R§
§
Valid only when the room walls are at 90° to each other.
PRT. NO.
DATE:
These instructions must be used in conjunction with the 'General Installation Instructions' for Masport
MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm)
MODEL
Important Note: Masport Mackenzie R10000 model needs to be installed with specific flue shield, flue divertor
plate and 500x500mm ceiling plate. The Glen Dimplex warranties will void unless fitted with these
components, which are supplied with the fire and Masport flue kit GDFLU013M.
‡ Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the relevant
manufacturer for their specification. Masport accepts no responsibility for the deterioration of surfaces or finishes.
400
550
778
Mackenzie R10000 (NZ)
(DRY & WET)
Mackenzie R10000
(SW)(Dry & Wet)
The minimum clearances to combustables may be reduced if the combustable walls are shielded with an approved
non-combustable material. Details of suitable materials and appropriate clearance reduction factors are present in
Section 3 of AS/NZS 2918:2001.
MODEL
INSTALLATION SPECIFICATION SHEET
POSITIONING YOUR FREE-STANDING WOODFIRE
350
This fire has been tested and complies to the Australian/New Zealand Standard AS/NZS 2918:2001 and all
installations must be in accordance with the minimum clearances to combustibles indicated in these instructions.
01.07.2014
CLEARANCE REQUIREMENTS
795
MASPORT FLUE + MASPORT 900mm
DOUBLE SKIN TOP FLUE
DIVERTER PLATE + 500x500 Ceiling Plate
NEW ZEALAND
150
FLUE SYSTEM & FLUE SHIELD
160
583571
Page 1 of 5