wood fires.

A

B

E

F

G

H

§ 

Valid only when the room walls are at 90° to each other.

PRT. NO. 

DATE:

These instructions must be used in conjunction with the 'General Installation Instructions' for Masport

 MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm)

MODEL

Important Note: Masport Mackenzie R10000 model needs to be installed with specific flue shield, flue divertor 

plate and 500x500mm ceiling plate.  The Glen Dimplex warranties will void unless fitted with these 

components, which are supplied with the fire and Masport flue kit GDFLU013M.

‡ Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the relevant 
manufacturer for their specification. Masport accepts no responsibility for the deterioration of surfaces or finishes.

400

550

778

Mackenzie R10000 (NZ)  

(DRY & WET)

Mackenzie R10000    

(SW)(Dry & Wet)     

The minimum clearances to combustables may be reduced if the combustable walls are shielded with an approved 
non-combustable material. Details of suitable materials and appropriate clearance reduction factors are present in 
Section 3  of AS/NZS 2918:2001.

MODEL

INSTALLATION SPECIFICATION SHEET

POSITIONING YOUR FREE-STANDING WOODFIRE

350

This fire has been tested and complies to the Australian/New Zealand Standard AS/NZS 2918:2001 and all 
installations must be in accordance with the minimum clearances to combustibles indicated in these instructions.

01.07.2014

CLEARANCE REQUIREMENTS

795

MASPORT FLUE + MASPORT 900mm 

DOUBLE SKIN  TOP FLUE 

DIVERTER PLATE + 500x500 Ceiling Plate

NEW ZEALAND

150

FLUE SYSTEM & FLUE SHIELD

160

583571

Page 1 of 5