![masosine SPS 100 Скачать руководство пользователя страница 83](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328083.webp)
23
The static flushing device
23.1 SPS 100
Fitting the static flushing device—SPS 100 pumps
The sight glass and the sight glass
connection piece
The tapped pump seal housing
•
The static flushing device can be fitted only to a SPS 100 pump with a pump seal housing which is
tapped to take it (arrowed). See also "Assembling the SPS 100" on page 43.
•
Pass the special L-shaped tool or a screwdriver through the top hole in the bearing housing and use
it to rotate the pump seal housing until it is central to the top hole in the bearing housing.
•
Fit the sight glass connection piece. Use a 17mm spanner to tighten it.
•
Fit the sight glass.
m-SPS-en-08
83