![masosine SPS 100 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328036.webp)
21.3 Adjusting dimension X in models with stainless steel power
frame
SPS 200, SPS 250, SPS 300, SPS 400 and SPS 500
Dimension X
Shim ring
Power frame
Bearing housing
Lip seals
Shaft
Bearing housing
retaining screw
Vernier
Power frame
Shim ring
Lip seals
Bearing housing
Bearing housing
retaining screw
Dimension X
Shaft
Vernier
Shaft
sleeve
Dimension X
SPS 100
SPS 200
SPS 250
SPS 300
SPS 400
SPS 500
10.0mm
+0.05
17.5mm
+0.1
17.4mm
+0.1
23.0mm
+0.1
15.0mm
+0.1
25.4mm
+0.1
Note
: SPS 100 pumps must be returned to MasoSine for dimension X adjustment.
•
Remove the front cover, the front support, the front liner, the rotor, the gate and the gate guide.
See "Disassembly and assembly" on page 38.
•
Measure dimension X.
•
Check this dimension against the table above.
36
m-SPS-en-08
Содержание SPS 100
Страница 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Страница 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Страница 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Страница 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Страница 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Страница 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Страница 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Страница 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Страница 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Страница 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...