7.8
Protective devices
All protective devices must be attached correctly and functioning before every start- up. Protective
devices may be removed only after the machine has stopped and protection measures against restarting
the machine have been taken.
After spare parts have been fitted, protective devices must be attached according to the operating
organisation’s regulations.
If contact with hot or cold machine parts could be dangerous, protection must be provided for the pump
user.
7.9
Dangers due to hazardous pumped material
If hazardous material is to be pumped, the appropriate regulations must be observed.
7.10 Dangers due to electrical energy
Work on the electrical supply must be performed only by an electrician.
Check the electrical equipment of the machine regularly. Rectify loose connections
and scorched cables immediately.
Keep the control cabinet locked closed or secured with a tool. Access is allowed only to authorised
personnel.
If work on parts conducting voltage must be done, call in a second person to switch off the mains power if
necessary.
Electrical connection of the pump must be made according to local regulations, by skilled personnel only.
7.11 Dangers due to hydraulic energy
Only personnel with special knowledge and experience in hydraulics may work on hydraulic devices.
Relieve the pressure in the system sections and pressure lines to be opened before starting repair work.
Replace hydraulic hose lines at appropriate intervals, even if no safety-relevant defects are detectable.
7.12 Special danger points
The pump contains a rotating rotor, which can crush or
sever fingers and hands. The pump must be guarded so
that it is not possible for people to hold the pump by its
inlet or delivery ports with the rotor running. When the
rotor is stationary, the drive must be secured against
unintentional start-up. Increased danger exists if pipes are
dismantled or the pump is open.
7.13 Constructional changes to the machine
Make no changes, attachments or conversions to the machine without the manufacturer’s approval. All
conversion measures require the written confirmation of Watson-Marlow GmbH MasoSine Division.
Replace machine parts which are not in perfect condition immediately. Use only original spare and
wearing parts. Parts that are not obtained from MasoSine are not guaranteed to be designed and
manufactured in compliance with load and safety requirements.
The warranty is invalid if genuine spare parts from MasoSine are not used.
7.14 Noise
The continuous sound pressure level proceeding from the machine should not exceed 70 dB(A). Higher
sound pressure levels that can cause deafness can arise, depending upon local conditions. If this occurs,
protect the operating personnel with appropriate protective equipment / protective measures.
7.15 Temperature
The pump bearing frame can heat up when in use and can reach a
temperature of about 70°C. Caution should be exercised, as this can cause
injury to the operator. In addition, the pump itself can heat up if hot product is
transferred.
10
m-SPS-en-08
Содержание SPS 100
Страница 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Страница 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Страница 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Страница 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Страница 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Страница 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Страница 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Страница 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Страница 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Страница 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...