![masosine Certa Plus Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/masosine/certa-plus/certa-plus_user-manual_1735326024.webp)
17
Heating and cooling option
Special versions of MasoSine P100, P200, P250, P300 and
P400 pumps can be heated or cooled to maintain the required
product temperature within the pump—pumping chocolate or
ice cream, for example—by passing fluid at the temperature
required through crescent-shaped channels in the pump
housing and the front housing. The pump has 1/8in
connections on two sides though which the heating or cooling
agent flows. The position of the connections varies depending
on the model. A possible backpressure should not exceed
1bar/15psi. The minimum flow required for the
heating/cooling option is 0.2l/min or 0.05gpm.
Note:
Most pump sizes can be retro-fitted to allow heating
and cooling (refer to table below).
Note:
The heating or cooling temperature must stay within
the temperature limits of the pump. These can be found in
"Limit values for the pump" on page 9
P100
P200
P250
P300
P400
Pump
housing
MP-HZG-G-P100
MP-HZG-G-P200
MP-HZG-G-P250
MP-HZG-G-P300
MP-HZG-G-P400
Front
cover
MP-HZG-D-P100
MP-HZG-D-P200
MP-HZG-D-P250
MP-HZG-D-P300
MP-HZG-D-P400
24