12.4 Possible pump orientations
The pump can be positioned in one of eight orientations, and can rotate clockwise or counter-clockwise.
10-02
12-03
02-04 *
03-06
04-08
06-09
08-10 *
09-12
Unless you specify otherwise when ordering, the pump is delivered in position 10-02.
Special customised nozzle orientations are possible.
*Please note: According to EHEDG regulations, the pump head should always be completely self-draining.
In a standard installation this can only be assured in the 02-04 or 08-10 nozzle position.
Changing the pump orientation
See See Disassembling the support / Changing the nozzle orientation on page 29 for details about
changing the pump orientation.
12.5 Connecting to a power supply
The motor must be connected according to local regulations by a qualified person.
See the instruction manual supplied with your drive motor.