background image

GENERAL SAFETY 
INFORMATION:  

 

 

Always read before proceeding.
 

 

 

WARNING
These instructions contain both information and warnings that are necessary for 
the safe operation and maintenance of this product. It is recommended that you 
read the instructions carefully and ensure that the contents are fully understood. 
Failure to understand and to comply with the warnings and instructions can result 
in serious injury, damage or even death.

In order to avoid the danger of electrical shock, it is important that proper safety 
measures are taken when working with voltages exceeding 30V AC rms, 42V AC 
peak or 60V DC.

This product must only be used by a competent person capable of interpreting 
the results under the conditions and for the purposes for which it has been 
constructed. Particular attention should be paid to the Warnings, Precautions and 

use and that there are no signs of damage to it. Do not use if damaged.

Where applicable other safety measures such as use of protective gloves, goggles 
etc. should be employed.

Please keep these instructions for future reference. Updated instructions and 
product information are available at: www.martindale-electric.co.uk

REMEMBER: SAFETY IS NO ACCIDENT. 
MEANING OF SYMBOLS:

 

Equipment complies with relevant EU Directives.

 

 End of life disposal of this equipment should be in 
accordance with relevant EU Directives.

     

Caution - risk of electric shock.

 

Caution - risk of danger & refer to instructions.

 

Equipment protected by double or reinforced insulation (Class II).

   

      Alternating current (AC).

1. INTRODUCTION
1.1 Inspection

Examine the shipping carton for any sign of damage. Inspect the unit and any 
accessories for damage. If there is any damage then consult your distributor immediately.

Measurement Category III (CAT III)

 is applicable to test and measuring equipment 

connected to the distribution part of the building’s low-voltage MAINS installation.

Measurement Category IV (CAT IV) 

is applicable to test and measuring equipment 

connected at the source of the building’s low-voltage MAINS installation.

2.1 Precautions

This product has been designed with your safety in mind, but please pay attention to the 
following warnings and cautions before use.

Warning

The voltage indicator must only be used by a skilled and competent person who is 
familiar with the relevant regulations, the safety risks involved and the consequent 
normal safe working practices.

Before each use the voltage indicator should be examined for damage, cracks, cuts or 
scratches. If there is any doubt the voltage indicator should 

not be used.

Make sure the voltage indicator is dry, clean and free from dust, grease and moisture 
while in use to avoid the danger from electric shock due to surface leakage.

Содержание VT7

Страница 1: ...Directives End of life disposal of this equipment should be in accordance with relevant EU Directives Caution risk of electric shock Caution risk of danger refer to instructions Equipment protected by double or reinforced insulation Class II Alternating current AC 1 INTRODUCTION 1 1 Inspection Examine the shipping carton for any sign of damage Inspect the unit and any accessories for damage If the...

Страница 2: ...r Two LED s one in the front cone and one above the test switch should illuminate and the buzzer should sound Do not use the voltage indicator if either of the LED s fails to illuminate or the buzzer fails to sound If both LED s and the buzzer do not function replace the battery see section 4 1 Battery Replacement and retest the unit 3 2 Proving Check Before and after use verify the voltage indica...

Страница 3: ...by the end user This warranty extends only to the original buyer or end user customer and does not apply to fuses disposable batteries test leads or to any product which in Martindale s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation handling or storage Martindale authorised resellers shall extend this warranty on new and unused pr...

Страница 4: ... C Humidity Operating Storage 85 R H Altitude up to 2000m General Power 9V PP3 alkaline battery IEC 6LR61 NEDA 1604A Current consumption 34mA max Dimensions 236 L x 44 W x 33 D mm Weight 120g battery included approx Includes 9V PP3 battery instructions Safety Conforms to BS EN61010 1 CAT IV 300V CAT III 600V Class II Double Insulation Pollution Degree 2 IP rating IP54 Water resistant EMC Conforms ...

Отзывы: