CONTENTS
1 Safety Information
1
1.1 Meaning of Symbols and Markings
1
1.2 Precautions
2
1.3 Safety Advice
4
2 Introduction
5
2.1 Inspection
5
2.2 Description
5
3 Operation
6
3.1 Description of LED Indicators
6
3.2 Use of Test Prod Shrouds
6
3.3 Operating Duty Ratio
7
3.4 Proving Check
7
3.5 Testing for the Presence of Hazardous Live Voltage
9
3.6 Interference (Phantom) Voltage
9
4
Maintenance
10
4.1 Periodic Testing
10
4.2 Cleaning
10
4.3 Repair and Service
10
4.4 Storage Conditions
11
5 Warranty
12
Specifications
1
1. SAFETY INFORMATION
REMEMBER: SAFETY IS NO ACCIDENT
These instructions contain both information and warnings that are
necessary for the safe operation and maintenance of this product. It
is recommended that you read the instructions carefully and ensure
that the contents are fully understood. Failure to understand and
to comply with the warnings and instructions can result in serious
injury, damage or even death.
Particular attention should be paid to the Warnings, Precautions and
Technical Specifications.
Please keep these instructions for future reference. Updated
instructions and product information are available at:
www.martindale-electric.co.uk
1.1 Meaning of Symbols and Markings
Caution - risk of danger & refer to instructions
Caution - risk of electric shock
Equipment protected by double or reinforced
insulation (Class II)
Suitable for live working
Both direct and alternating current (AC and DC)
CAT IV (Measurement Category IV)
is applicable to test and
measuring equipment connected at the source of the
building’s low-voltage MAINS installation.
2
For further information on measurement categories visit
www.martindale-electric.co.uk/measurement_categories.php
Equipment complies with relevant EU Directives
End of life disposal of this equipment should be in
accordance with relevant EU Directives
1.2 Precautions
This product has been designed with your safety in mind, but please
pay attention to the following warnings and cautions before use.
Warnings
In order to avoid the danger of electrical shock, it is important that
proper safety measures are taken when working with voltages
exceeding 30V AC rms, 42V AC peak or 60V DC.
Where applicable other safety measures such as the use of protective
gloves, goggles etc. should be employed.
The voltage indicator must only be used by a skilled and competent
person who is familiar with the relevant regulations, the safety risks
involved and the consequent normal safe working practices.
Before each use the voltage indicator should be examined for
damage, cracks, cuts or scratches to the housing, cable and prods.
The cable has black outer and contrasting inner insulation, to allow
damage to the cable to be easily identified. If there is any doubt the
voltage indicator should
not be used
.
Make sure the voltage indicator is dry, clean and free from dust,
grease and moisture while in use to avoid the danger from electric
shock due to surface leakage.