background image

2

CAT III 

   

(Measurement Category III)

 is applicable to test and 

measuring equipment connected to the distribution part of 

the building’s low-voltage MAINS installation.

CAT IV    (Measurement Category IV) 

is applicable to test and 

measuring equipment connected at the source of the 

building’s low-voltage MAINS installation.

  

 

For further information on measurement categories  
see page 21 or visit  
www.martindale-electric.co.uk/measurement_categories.php

 

 

Equipment complies with relevant EU Directives

 

 End of life disposal of this equipment should be in accordance 

with relevant EU Directives.

1.2 Precautions

This product has been designed with your safety in mind, but please 

pay attention to the following warnings and cautions before use.

Warnings 

In order to avoid the danger of electrical shock, it is important that 

proper safety measures are taken when working with voltages 

exceeding 30V AC rms, 42V AC peak or 60V DC.

 

Where applicable other safety measures such as the use of protective 

gloves, goggles etc. should be employed.

 

The multimeter must only be used by a skilled and competent person 

who is familiar with the relevant regulations, the safety risks involved 

and the consequent normal safe working practices, and under the 

3

conditions and for the purposes for which it has been constructed 

and specified.

 

Before each use the multimeter and any associated test leads 

and accessories should be examined for damage, cracks, cuts or 

scratches. 

Do not use

 if damaged in any way.

 

Make sure the multimeter and test leads are dry, clean and free from 

dust, grease and moisture while in use to avoid the danger from 

electric shock due to surface leakage.

Always test this unit on an appropriate proving device or a known 

good voltage source before and after using it to determine if a 

hazardous voltage exists in a circuit to be tested. 

Do not use

 the 

unit if it does not function correctly during proving.

 

Measuring/testing for a voltage/current that exceeds the specified 

limits of the unit may damage the unit and may expose the operator 

to a shock hazard. Always check the unit’s specified limits before 

use.

 

The multimeter must only be used on CAT IV installations up to 

600V to earth, CAT III and CAT II installations up to 1000V to earth, 

and within the operating temperature and humidity range specified.

 

The CAT III 1000V marking does not mean the clamp meter can 

be used to 1000V AC rms, but that it will be safe to the user if 

inadvertently connected across a voltage up to 1000V AC rms to 

earth.

 

 

If the removable probe tip caps are not fitted to the probes of the test 

leads, their measurement category becomes CAT II 1000V, and they 

4

must not be used

 on CAT III or CAT IV installations to avoid the 

risk of shorting high energy circuits and arc flash.

 

When this unit is used in combination with test leads, the 

measurement category of the combination is the lower 

measurement category of either this unit or the test leads used. 

Likewise if test lead accessories such as crocodile clips are also 

used, the measurement category will be the lowest measurement 

category in that combination.

 

Do not use

 if the battery compartment cover is not fitted.

 

When using test leads, 

always

 keep your fingers behind the finger 

guard on the test lead probe.

 

To avoid electrical shock, and damage to the multimeter, do not use 

the multimeter and the associated temperature probe when voltages 

at the measurement surface exceed 30V AC rms or 60V DC.

Cautions

Avoid severe mechanical shock or vibration and extreme 

temperature.

 

When using test leads avoid excessive stresses to the cable entry 

points at the probe and 4mm plug connector.

 

To avoid burns or damage to equipment, do not take temperature 

measurements inside microwave ovens.

 

To avoid possible corrosion from a leaking battery, remove the 

battery when the unit is not in use for an extended period.

5

2. INTRODUCTION

2.1 Inspection

Examine the shipping carton for any sign of damage. Inspect the 

unit and any accessories for damage. If there is any damage then 

consult your distributor immediately.

2.2 Description

The Martindale MM94 has the following measurement functions:

‹

  True rms AC voltage to 750V

‹

  DC voltage to 1000V

‹

  True rms AC current to 20A

‹

  DC current to 20A

‹

 Resistance to 60M

:

‹

 Conductance to 60nS

‹

  Capacitance to 6mF

‹

 Frequency to 10MHz

‹

 Duty cycle

‹

  Temperature (Type K thermocouple)

‹

  Continuity with audible indication

‹

 Diode testing

Further functions are:

‹

 Display hold

‹

 Min/Max indication

‹

 Peak hold measurement 

‹

  Selectable high frequency rejection

‹

 Relative function

‹

  Selectable 6000 or 60000 count display

‹

 Display backlight

Содержание MM94

Страница 1: ...Measurements 15 3 24 Continuity Testing 15 3 25 Diode Testing 16 4 Maintenance 16 4 1 Battery Replacement 16 4 2 Fuse Replacement 17 4 3 Test Lead Replacement 17 4 4 Calibration 17 4 5 Cleaning 18 4 6 Repair Service 18 4 7 Storage Conditions 18 5 Warranty 19 Measurement Categories 20 Specifications 1 1 SAFETY INFORMATION Always read before proceeding REMEMBER SAFETY IS NO ACCIDENT These instructio...

Страница 2: ...th CAT III and CAT II installations up to 1000V to earth and within the operating temperature and humidity range specified The CAT III 1000V marking does not mean the clamp meter can be used to 1000V AC rms but that it will be safe to the user if inadvertently connected across a voltage up to 1000V AC rms to earth If the removable probe tip caps are not fitted to the probes of the test leads their...

Страница 3: ... of LCD Symbols 7 HFR1 High frequency reject 1 kHz selected HFR 2 High frequency reject 100 kHz selected RANGE Manual ranging is selected MAX Maximum indication is displayed MIN Minimum indication is displayed HOLD Display hold is activated P Indicates peak measurement P Indicates peak measurement REL Relative function selected Indicates 30V at input terminals AC Indicates AC measurement DC Indica...

Страница 4: ...ions connect the test leads to the circuit being measured and read the measured ac voltage from the display 11 3 15 DC Voltage Measurements Connect the black test lead to the COM terminal and the red test lead to the terminal Set the rotary switch to the or position as required Taking all necessary safety precautions connect the test leads to the circuit being measured and read the measured dc vol...

Страница 5: ... if d600 15 3 25 Diode Testing If the diode to be tested is in circuit be sure the circuit power is switched off Connect the black test lead to the COM terminal and the red test lead to the terminal Set the rotary switch to the position Press the SHIFT button twice The LCD will display the symbol Taking all necessary safety precautions connect the test leads to the diode being tested If the diode ...

Страница 6: ...ered neglected contaminated or damaged by accident or abnormal conditions of operation handling or storage Martindale authorised resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Martindale Martindale s warranty obligation is limited at Martindale s option to refund of the purchase...

Страница 7: ...range Crest factor 3 at full scale 6 at half scale Peak hold accuracy on AC current ranges 45Hz to 500 Hz 3 5 rdg 500 dts Peak hold response time 1ms Input protection 0 5 A 1000 V fast blow ceramic fuse on 600μA to 400mA ranges 20A 600V fast blow ceramic fuse on 20 A range Note 1 Apply currents 10 A for 30 seconds maximum then allow a 10 minute cooling period Specification MM94 TRMS Digital Multim...

Страница 8: ...0 R H Altitude up to 2000m Pollution degree 2 indoor use SAFETY Conforms to BS EN 61010 1 BS EN 61010 2 033 CAT IV 600V CAT III 1000V Class II double insulation EMC Conforms to BS EN 61326 1 Specification MM94 TRMS Digital Multimeter SPECIFICATION FOR TL16 TEST LEADS Maximum voltage 1000V AC DC Maximum current 10A continuous Connector 4mm banana plug with fixed shroud Environmental Temperature Ope...

Отзывы: