PROVING UNITS

Instruction

Manual

PD440S
PD690S

PD440S PD690S instruct  V1.indd   2

02/09/2019   13:12:26

Содержание PD440S

Страница 1: ...PROVING UNITS Instruction Manual PD440S PD690S PD440S PD690S instruct V1 indd 2 02 09 2019 13 12 26...

Страница 2: ...1 Meaning of Symbols and Markings 1 1 2 Precautions 2 2 Introduction 3 2 1 Inspection 3 2 2 Description 3 2 3 Accessories 3 2 4 Battery Installation 3 3 Operation 4 3 1 Proving Unit LED Indications 4...

Страница 3: ...death Particular attention should be paid to the Warnings Precautions and Technical Specifications Please keep these instructions for future reference Updated instructions and product information are...

Страница 4: ...k or 60V DC Before use check the unit for cracks or any other damage Make sure the unit is free from dust grease and moisture Also check any associated accessories for damage Do not use if damaged Do...

Страница 5: ...ortable battery powered proving unit for the testing of contact type voltage detectors up to 690V Model High Voltage Output Frequency High Voltage LED Low Battery LED PD440S 440V 50Hz PD690S 690V 50Hz...

Страница 6: ...w Replace batteries 3 2 Proving a Test Lamp Voltage Tester Indicator DMM etc Place one probe of the unit under test into the left hand socket of the proving unit until it makes contact with the termin...

Страница 7: ...em if required see section 4 1 3 3 Test Lamp Voltage Tester Indicator Cables During the above tests emphasis should also be placed upon the flexing of the UUT cable along its length and particularly a...

Страница 8: ...thoroughly cleaned with a water dampened soft cloth After cleaning dry and allow to remain in a dry environment for 2 hours before use 4 3 Repair and Service There are no user serviceable parts in thi...

Страница 9: ...r replacement of a defective product which is returned to Martindale within the warranty period This warranty is the buyer s sole and exclusive remedy and is in lieu of all other warranties expressed...

Страница 10: ...ts Output loading See typical output voltage vs loading graph Environmental Operating temperature 10 C to 40 C at max 70 R H Altitude up to 2000m Pollution degree 2 General Power Internal batteries In...

Страница 11: ...Circuit MTL10 MTL20 MTL7 6k Load resistance K Ohms Output Voltage V rms Typical Output Voltage vs Loading 1000 100 10 1 700 600 500 400 300 200 100 2K MTL9C 4K VI13700G 80K 70K 40K 20K PD690S PD690SX...

Страница 12: ...V1 18th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration Repair Service Fuse Finders Digital Clamp Meters Digital Multimet...