Martin Stagebar 2 RGBAW Скачать руководство пользователя страница 1

Stagebar 2

RGBAW

user manual

TM

Содержание Stagebar 2 RGBAW

Страница 1: ...Stagebar 2 RGBAW user manual TM...

Страница 2: ...ion in writing from Martin Professional A S Information subject to change without notice Martin Professional A S and all affiliated companies disclaim liability for any injury damage direct or indirec...

Страница 3: ...before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes a...

Страница 4: ...t persons are not looking at the LEDs from within 8 7 meters 28 ft 7 ins when the product lights up suddenly This can happen when power is applied when the product receives a DMX signal when stand alo...

Страница 5: ...DMX channel requirements 13 DMX addresses 13 Fixture readouts 13 Other control menu features 14 Operation 15 Color control 15 Stand alone operation 15 Service and maintenance 16 Adjustable floorstand...

Страница 6: ...the next fixture The total current draw of all the devices connected to the power throughput outlet of the first fixture in the chain must not exceed 15 amps peak 11 amps constant F Quarter turn moun...

Страница 7: ...MX data connectors For the latest firmware updates documentation and other information about this and all Martin Professional products please visit the Martin website at http www martin com Comments o...

Страница 8: ...fixtures vertically and secure stacked fixtures so that they cannot fall over Flying from a truss bar or other structure To fly a fixture from a rig or other structure 1 Check that the supporting str...

Страница 9: ...a 4 amp slow blow primary fuse located in a fuseholder on the rear panel see Figure 1 on page 6 Connecting to power Power is supplied to the fixture via a blue Neutrik PowerCon inlet that accepts a bl...

Страница 10: ...al of 10 A which is within the 11 A limit for constant current draw At 230 V AC power a maximum of 11 Stagebar 2 fixtures may be linked in one chain so that they draw AC power from the same source Eac...

Страница 11: ...channels available If individual control of the Stagebar 2 fixtures in an installation is required each fixture must be given its own channels until the limit of 512 is reached At this point a new DMX...

Страница 12: ...ensity of each color is controlled on one DMX channel giving RGB additive color mixing RGBAW red green blue amber white RGBAW is a raw control mode in which the intensity of each color LED is controll...

Страница 13: ...ddresses The DMX address also known as the start channel is the first of the DMX channels used to receive instructions from the controller If two fixtures are set to the same mode and share the same D...

Страница 14: ...urposes Software upload Select UTILITIES software upload before uploading new software Restoring factory settings UTILITIES factory setting reloads the default factory settings Switching between cooli...

Страница 15: ...rs are active in all color control modes Stand alone operation In stand alone operation the Stagebar 2 can be programmed to run two types of display without the need for a DMX controller A static colo...

Страница 16: ...optical and color parameters The manufacturer s LED lifetime data is based on performance under the manufacturer s test conditions As with all LEDs the gradual reduction in luminous output will be acc...

Страница 17: ...screw arrowed slightly and slide the assembly out of the end cap for access Do not strain the wires to the fan Brush dirt from the fan blades with a soft brush preferably in conjunction with a vacuum...

Страница 18: ...low it to cool for at least 10 minutes 2 See Figure 4 Loosen the two captive screws arrowed on the end cap and swing the end cap open 3 Slide the opal front cover out of its slots in the front of the...

Страница 19: ...wer version Software updates are available from the Martin website http www martin com and can be installed via the DMX data link with the following items The Stagebar 2 main CPU software update file...

Страница 20: ...20 Stagebar 2 user manual 5 Check that the fixture resets correctly If a checksum error occurs cycle power off and on again and check that the fixture now resets correctly...

Страница 21: ...nel Value Percent Function 1 0 255 0 100 Red Intensity 0 100 2 0 255 0 100 Green Intensity 0 100 3 0 255 0 100 Blue Intensity 0 100 Channel Value Percent Function 1 0 255 0 100 Red Intensity 0 100 2 0...

Страница 22: ...in the Stagebar 2 Channel Value Percent Function 1 0 255 0 100 Hue Red Orange Amber Yellow Green Cyan Blue Indigo Violet Magenta Red 2 0 255 0 100 Saturation Zero white Full saturation 3 0 255 0 100...

Страница 23: ...xels at same time pixel invert on Pixels swapped left to right 1 moved to 6 2 moved to 5 etc off Pixels normal STAND ALONE sa setup stand alone off Disable stand alone operation static colour Enable s...

Страница 24: ...hest driver PCB temperature since manufacture temp pixel current Display current average pixel PCB temperature max since reset Display highest pixel PCB temperature since last fixture reset max record...

Страница 25: ...CO D3CO D4CO D5CO D6CO there is a temperature error on a driver PCB 1 6 identifies the PCB involved CO Cutoff Contact Martin Service for assistance P1CO P2CO P3CO P4CO P5CO P6CO there is a temperature...

Страница 26: ...service technician or device supplier One or more fixtures displays stand alone sequences incorrectly or not at all Fixtures incorrectly set up Check settings in control menus Fault on DMX link Inspe...

Страница 27: ...display Display Battery powered backlit LCD 2 x 16 character 16 bit control internal RGBAW RGB HSI HSIC color mixing DMX protocol USITT DMX512 A Receiver RS 485 Firmware update Serial upload via DMX l...

Страница 28: ...r Narrow diffuser filter Neutrik PowerCon NAC3FCA power input connector cable mount blue P N 05342804 Omega rigging clamp attachment bracket with quarter turn fasteners P N 91602001 User manual P N 35...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...