The functions of each DMX control channel are as follows: 
 

Channel 1  DMX value 

range 

Function

Macro description 

Default 

value 

Haze 

output 

Level 

0-12

Idle range

None

13- 24

Haze 5%

25- 36

Haze 10%

……..

…….

245 -255

Haze 100%

Channel 2  DMX value 

range 

Function

Macro description 

Default 

value 

Fan 

output 

level (fan 

will always 

run if haze 

is active) 

0-12

Idle range

None

13-24

Fan 5%

25-36

Fan 10%

……..

…….

245 -255

Fan 100%

Channel 3  DMX value 

range 

Function

Macro description 

Default 

value 

Special 

functions 

0-50

Idle range

None

51-100

Prime

5 seconds within 

range to activate 

once 

101-150

Auto Fan 

mode 

None (level 

triggered) 

151-200

Heater off & 

shutdown 

5 seconds within 

range to activate 

once 

201-255

Heater on 

(normal 

operation) 

None, but heaters 

will stay on if 

channel 3 returns to 

zero 

 
 
 
 

RDM o peration 

The Jem Ready 365™ supports DMX Remote Device Management (RDM). This 
allows configuration and status monitoring of the machine from a suitably 
equipped lighting console or control system. 
 

The following can be configured using RDM: 
Set/read DMX start address 
Set/read RDM device label 
Reset device 
Reset options to factory defaults 

 
The following parameters can be read using RDM: 
Device status (ready, heating, gas errors) 
DMX “slot” functions (channel functions) 
Device software version 

Device model/manufacturer 
Service Data 
 
 

Содержание JEM Ready 365

Страница 1: ...user manual P N 35010035 E ...

Страница 2: ...ct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A S or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional A S or...

Страница 3: ...de 14 Setting Haze density 14 Setting Fan speed 14 Setting the Timer 14 Setting the DMX base address 15 Setting the master slave link mode 15 Checking gas pressure 15 Priming the machine after fluid out 15 Resetting options to factory settings 16 Aux menu 16 Remote control 17 Overview 17 Functions 17 Connection 17 DMX control 18 Overview 18 Connection 18 DMX functions 18 RDM operation 19 Haze flui...

Страница 4: ...both overload and ground fault protection Before connecting the haze machine to power check that the voltage indicated on the machine s serial label matches your local AC power voltage If your AC power voltage does not match do not use the machine Contact Martin Service for assistance Before using the machine check that all power distribution equipment and cables are in perfect condition and rated...

Страница 5: ...vents and ensure free and unobstructed air flow to and around the machine Keep the machine at least 60cm 24 inches away from combustible and heat sensitive materials Do not operate the machine if the ambient temperature Ta is below 5 C 41 F or above 40 C 104 F Do not operate the machine if the relative air humidity exceeds 80 Preventing injuries Ensure that the surface on which the machine is loca...

Страница 6: ...tions on page 20 or you may cause the release of toxic gases presenting a severe health hazard You will also probably damage the machine Do not create dense haze in confined or poorly ventilated areas Do not expose people with health problems including allergic and or respiratory conditions such as asthma to haze output Do not point haze output directly at a person s face or at face height ...

Страница 7: ... smooth distribution while a unique mixing channel allows the haze to optimize before being expelled Congratulations on your purchase of the Jem Ready 365 from Martin Details of the full range of Martin products are available on our website at www martin com Features at a glance Finest haze production in its class Small particle even haze Continuous output 5 minute heat up time Water based fluid w...

Страница 8: ...emperature vapour and surfaces Power link out connector Main power switch CO2 gas connector AVR program upload socket 3 pin DMX input and link Digital remote socket Fluid tank under hinged cover Haze output port 5 pin DMX input and link Power inlet connector Haze deflector ...

Страница 9: ...e rear of the machine The display will show HEAT then after about 5 6 minutes the machine will reach operating temperature If the display shows OFF press the RUN button to the right of the display Making haze If the machine does not automatically start making haze press the RUN quick access button to the right of the display Press RUN again to stop the haze If you want to change the haze density p...

Страница 10: ... For US 120V use fit a plug rated 10 amp minimum When installing the plug follow the plug manufacturer s instructions and connect pins as follows Yellow and green wire to ground earth blue wire to neutral and brown wire to live The table below shows some common pin identification schemes wire function marking screw colour brown live L yellow or brass blue neutral N silver green yellow earth green ...

Страница 11: ...ze deflector flap on the front of the machine can be positioned in either the raised position so the haze goes up into the air or in the lowered position to reduce air turbulence Final checks Before applying power to the haze machine verify the following the machine is safely located or installed and meets the location requirements stated on page 10 the operator is familiar with and able to comply...

Страница 12: ...run a self cleaning cycle after power down to help prevent blockages It uses an internal rechargeable battery to do this If cleaning is needed when the power is disconnected the display will show then counting down to will scroll across the display The unit will then automatically power down If the unit is not to be used for some time turn off the valve on the CO2 cylinder ...

Страница 13: ...55 Fan 20 Haze 20 Fan 20 The buttons to the right of the display change the operating mode Press RUN to turn on haze in continuous run mode The display shows To stop the haze press the Run button again to set the machine to Standby mode heaters remain on Press SILENT to engage a low noise mode which slows down the fan If the RUN button is used to stop the haze Silent mode is not cancelled Silent m...

Страница 14: ...achine is powered up This applies to all options Setting Fan speed Use the Previous Next buttons to select the option Use the Up Down buttons to select the fan speed from Press the Enter button to store the fan setting The fan will run continuously if set above 0 and the RUN menu is set to FAN TIME or CONT If haze is being produced and the fan is off or set to a low speed the fan speed will be aut...

Страница 15: ... button to display the recorded value The display will show the gas pressure in PSI which should be about 34 when running at 100 output not in silent mode This information is for diagnostic use only and has no effect on the operation of the machine gas pressure control being fully automatic To disable the PSI display use the menu forward back keys or wait for a time out of the display to occur The...

Страница 16: ...n for the machine Use the Previous Next buttons to select the option Use the Up Down buttons to change the option to Press the Enter button to reset all options To exit this menu if you decide not to reset the options select and press Enter The factory settings are option setting HAZE FAN TRUN seconds TOFF seconds RUN ADDR LINK ALT PRME Aux menu The Aux menu currently has no function on this machi...

Страница 17: ...FF STBY FAN TIME CONT The functions are the same as on the built in control panel and are described on page 13 The RUN menu duplicates the functions of the Haze and Timer buttons The buttons are simply a quick way to control this menu function Connection The remote control has two identical XLR sockets on the top and back for connection to the Jem Ready 365 Plug the cable provided with the remote ...

Страница 18: ... to the 3 pin IN socket may be continued through the 5 pin OUT socket and vice versa Do not however attempt to split a DMX line by using both the 3 pin and 5 pin OUT sockets For best results use cable designed for high speed digital data transmission Suitable DMX cable is available from your Martin dealer DMX functions The Jem Ready 365 address setting must match the DMX address allocated to it on...

Страница 19: ...ange to activate once 101 150 Auto Fan mode None level triggered 151 200 Heater off shutdown 5 seconds within range to activate once 201 255 Heater on normal operation None but heaters will stay on if channel 3 returns to zero RDM operation The Jem Ready 365 supports DMX Remote Device Management RDM This allows configuration and status monitoring of the machine from a suitably equipped lighting co...

Страница 20: ...r use DANGER The Jem Ready 365 can run safely only on the specific haze fluid it is designed for Use ONLY the Martin haze fluid designated in this manual NEVER use any other type of fluid or toxic gas may be produced You will probably also cause damage to the system that will invalidate the product warranty Do not dilute haze fluid with water or any other liquid Discard haze fluid if it becomes co...

Страница 21: ...a period after use Remove dust from the air vents with a soft brush cotton swab vacuum or compressed air Clean haze fluid residues from the haze output of the machine using a damp cloth Clean the outer casing with a damp cloth only Fuse replacement The two fuses for the haze machine are located on the electronics board inside the unit DANGER Disconnect the power supply before removing any covers L...

Страница 22: ...ller DMX address setting incorrect Change DMX address page 14 Poor connection in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECV Haze output is weak Machine requires priming Prime machine page 15 Wet greasy non uniform haze output fluid drips or spits from nozzle or very loud noise when firing machine Incompatible haze fluid Use approved fluid Machine appea...

Страница 23: ...Service The machine has detected an error in the temperature sensor and will not operate Call Martin Service The machine is running a cleaning cycle which lasts 90 seconds number may be 89 to 0 There is no gas pressure in the cylinder The gas pressure is too low to operate and the machine will turn off in approximately 20 minutes on start up The internal battery is low and the last shutdown did no...

Страница 24: ...ystem Type Inert gas CO2 Supply type Vapour take off ONLY Storage External gas cylinder self sealing quick connector Pressure management Pressure readout low pressure warning OFG Out oF Gas system Typical gas consumption 250g 8 8 oz per hour Connections DMX data 5 or 3 pin XLR Remote machine link 3 pin XLR AC power Neutrik PowerCon Electrical AC power EU models 220 240V 50 60Hz AC power US models ...

Страница 25: ...ection hose with 9mm and 3 8 BSP connectors Ordering information Jem Ready 365 Hazer 120V 50 60Hz 92225975 Jem Ready 365 Hazer 230V 50 60Hz 92225970 Accessories Remote Control JEM Ready 365 92765041 CO2 pressure regulator Country specific Flight cases which have been custom designed for transportation and storage of the Jem Ready 365 are available directly from www swanflight com Specifications su...

Страница 26: ...92620015 R365 REG USA USA Canada Brazil 92620016 R365 REG DE Germany 92620017 R365 REG FR France Belgium North Africa 92620018 R365 REG Custom Contact Factory 92620019 R365 REG NL Netherlands 92620020 R365 REG JPN Japan 92620021 R365 REG RU Russia Should you wish to use a regulator other than the Martin approved units above please ensure that the regulator adheres to the following specifications C...

Страница 27: ...arliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products ...

Страница 28: ...www martin com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...

Отзывы: