100 Series User Manual
6. Check that all installation work is completed and carry out appropriate tests and safety checks before
applying power.
Installing a temporary power plug
It is possible to install a power plug on the power cable for temporary use (such as setting up a fixture
before installation, for example) only. If you choose to do this, install a grounding type (earthed) plug with
integral cable grip that is rated minimum 277 V, 6 A. Follow the plug manufacturer’s instructions and
connect the wires in the power cable as shown in the following table:
Live or L
Neutral or N
Earth, Ground or
US system
black white
green
EU system
brown blue
yellow/green
Power plug connections