background image

12 Exterior 

Wash

TM

 100 Series User Manual 

 

 

Referring to the illustration below, fasten the center of the yoke with a 12 mm (1/2 inch) shaft diameter bolt 
in the center hole 

A

. Then use two bolts with 8 mm (5/16 inch) shaft diameter passing through the curved 

slots 

B

 to anchor the fixture. Use washers and locking nuts. This setup will give approximately 90° of pan 

adjustment. 

 

Mounting yoke base dimensions 

 

Suspending from a truss 

In temporary installations, you can suspend the fixture from a rigging truss by means of a rigging clamp 
that is approved for the weight of the fixture securely fastened through the hole in the center of the yoke 
base (

A

 in illustration above). The fixture must be installed hanging vertically downwards only.  

When using a rigging clamp, secure the fixture with a safety cable (or similar secondary attachment) that 
is approved for the weight of the fixture so that the safety cable will hold the fixture if the rigging clamp 
fails. Loop the safety cable through the safety cable attachment point on the back of the fixture (see 
‘Fixture overview’ on page 9). Remove as much slack as possible from the safety cable (by looping it more 
than once around the truss chord, for example). 

Check that the truss and all fasteners used can support 10 times the weight of all the fixtures and 
equipment that they will support. 

Adjusting tilt 

 

Warning! The fixture can become hot. Wear heat-resistant gloves if you adjust the 
aim of the fixture when it is (or has recently been) powered on. 

Tilt adjustment can be carried out with the fixture powered on as 
follows. 
1.  Put on heat-resistant gloves. 
2.  See illustration on right. Loosen, but do not remove, the tilt lock 

screws (arrowed) on both sides.  

3.  Tilt the fixture to the desired angle and retighten the screws. 

 

Содержание Exterior Wash 100

Страница 1: ...Exterior Wash 100 Series User manual...

Страница 2: ...the information contained in this document 2013 2018 HARMAN Professional Denmark ApS All rights reserved Martin is a registered trademark of HARMAN Professional Denmark ApS registered in the United S...

Страница 3: ...Connecting to power 15 Control data link 17 Connecting the data link 17 Setup 19 Accessing and navigating the control menus 19 DMX settings 19 Programming a standalone show 20 Manual mode 21 Display s...

Страница 4: ......

Страница 5: ...re hazard or a risk of eye injury if the safety precautions below are not followed Respect all locally applicable laws codes and regulations when installing operating or servicing the fixture If you h...

Страница 6: ...ing water pollution temperature and UV resistance Protection from burns and fire Do not operate the fixture if the ambient temperature Ta exceeds 45 C 113 F The surface of the fixture can reach up to...

Страница 7: ...them At distances greater than 1 6 m 5 25 ft potential eye and skin injury hazards from the light output are normally prevented by natural aversion reflexes Position the Exterior Wash 100 so that pers...

Страница 8: ...to a rigging clamp Do not use safety cables as the primary means of support If the fixture is installed in a location where it may cause injury or damage if it falls provide a secondary attachment su...

Страница 9: ...ructures building features and landscaping All models have a built in display for ease of use a wide selection of beam angles and sealed construction suited to permanent outdoor use A discreet optiona...

Страница 10: ...or setting up the fixture before it is hard wired to a mains supply install a local power plug not supplied to the end of the supplied power cable 4 Before operating ensure that the voltage and frequ...

Страница 11: ...sh 100 Series fixtures must be corrosion resistant and strong enough to mount the fixture safely A washer must be installed directly under the head of each fastener when anchoring the base of the moun...

Страница 12: ...with a safety cable or similar secondary attachment that is approved for the weight of the fixture so that the safety cable will hold the fixture if the rigging clamp fails Loop the safety cable thro...

Страница 13: ...m angle 110 model Half peak beam angle 100 120 models None 10 7 Narrow 91610145 10 14 12 Medium 91610146 20 22 21 Wide 91610147 40 41 40 Very Wide 91610148 60 61 60 Asymmetric 91610149 10 x 60 14 x 61...

Страница 14: ...al snoot for Exterior Wash 100 Series fixtures may be installed with or without a diffuser lens see above To install shut down power to the fixture then align the snoot to fit over the front of the fi...

Страница 15: ...is easily accessible and is located close to the fixtures Do not use an external dimming system to supply power to the fixture as this may cause damage to the fixture that is not covered by the produc...

Страница 16: ...able for temporary use such as setting up a fixture before installation for example only If you choose to do this install a grounding type earthed plug with integral cable grip that is rated minimum 2...

Страница 17: ...the end of each branch by placing a 120 ohm resistor available from Martin P N 04150308 across the data output hot ve and data output cold ve conductors of the last fixture in the chain Avoid creatin...

Страница 18: ...r shell as this may cause interference Wires Input pair red tube Output pair black tube Shield Wire color White green Green White brown Brown Black Signal DMX in DMX in DMX out DMX out Common Male XLR...

Страница 19: ...green blue and white LEDs Since fixtures are uncalibrated slight differences in color and or intensity between different fixtures may be visible in the light output from multiple fixtures but you can...

Страница 20: ...same DMX control mode may share the same address and control channels if identical behavior is desired The DMX address may be set from the control panel or by RDM To set the fixture s DMX address fro...

Страница 21: ...s ENTER Display auto turn off The display can be set to stay on or to turn off 1 minute after the last key press To set display behavior 1 Access the control menu and select DISPLAY SETTINGS Press ENT...

Страница 22: ...fixtures This means that standalone operation is only possible if no DMX signal is present If you want master slave operation set only the first fixture on the link to MASTER Set all the other fixtur...

Страница 23: ...changes 4 Press ENTER White balance In Exterior Wash 100 and 110 models you can modify the white balance of the fixture s output by adjusting the amount of each color used in the mix to give white To...

Страница 24: ...t to reduce the risk of unauthorized access to the control menus you can set the fixture to require a user password before the control panel becomes operative Password protection is disabled by defaul...

Страница 25: ...mple shown but all Exterior Wash fixtures are similar Setting Effects Speed via RDM The example below shows how you can change the speed at which the fixture changes effects from Slow optimized for sm...

Страница 26: ...o not use products that contain solvents abrasives or caustic agents for cleaning as they can cause surface damage to the fixture The aluminum housing and front glass can be cleaned with mild detergen...

Страница 27: ...ability to control overall intensity level on DMX channel 1 Output is not calibrated Channel Value Function 1 0 255 Dimmer 0 100 2 0 255 Red 0 100 3 0 255 Green 0 100 4 0 255 Blue 0 100 5 0 255 White...

Страница 28: ...and 2 Channel 3 gives color temperature control from warm to cold at maximum output intensity When set to a level above 26 channel 3 overrides channels 1 and 2 Channel Value Function 1 0 255 Warm Whit...

Страница 29: ...0 255 Edit Scene Color Exterior Wash 120 1 last scene Cold white 0 255 Individual scene color temperature Warm white 0 255 Fade Time 0 120 secs 3 secs Transition time between scenes Hold Time 0 600 s...

Страница 30: ...Dimming behavior see page 22 Square Law Inverse Square Law S Curve Effects speed Fast Optimize effects for speed Slow Optimize effects for smoothness White Balance Exterior Wash 100 and 110 Red 90 10...

Страница 31: ...nk defective Check number of DMX channels required by each fixture and check DMX addresses on fixtures and DMX controller Check fixture s DMX MODE setting Inspect connections and cables Correct poor c...

Страница 32: ...Receiver RS 485 Firmware update Serial upload via DMX link DMX compliance USITT DMX512 A RDM compliance ANSI ESTA E1 20 Exterior Wash 100 and 110 DMX channels 3 4 or 5 Exterior Wash 120 DMX channels...

Страница 33: ...ge Maximum total power consumption 50 W Typical half cycle RMS inrush current at 240 V 50 Hz 9 7 A Typical power and current Exterior Wash 100 100 V 60 Hz 0 5 A 42 W PF 0 99 120 V 60 Hz 0 4 A 42 W PF...

Страница 34: ...es wide beam diffuser kit P N 91610147 Exterior Wash 100 Series very wide diffuser kit P N 91610148 Exterior Wash 100 Series asymmetric diffuser kit P N 91610149 Exterior Wash 100 Series glare shield...

Страница 35: ...uipment where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin produ...

Страница 36: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Отзывы: