Содержание MR11A7

Страница 1: ...1 marson MR11A7 Mobile UHF RFID Reader User Manual V 1 8 2018 8 7...

Страница 2: ...ration Mode 26 3 Operating the RFID Utility 27 3 1 Introduction to Main Window 27 4 RFID Parameters Setup 29 4 1 Operation Mode 29 4 2 Read Mode 30 4 2 1 Single Tag Read or Multi Tag Read 30 4 2 2 1 S...

Страница 3: ...5 2 Time Format 47 5 3 Communication Interface 48 5 4 Memory Communication Interface Options 49 5 4 1 Field Separator 49 5 5 BT HID and BT SPP Communication Interface Options 49 5 5 1 BT ID 49 5 5 2...

Страница 4: ...esh simple and clean The plastic shell is curved fashionably shaped and in harmony with mobile phones and tablet usage Industry Level Protection The MR11A7 is a Mobile UHF RFID Reader featuring a 1 5...

Страница 5: ...and Strap 3 One 1 Micro USB cable 4 One 1 Battery 5 One 1 Quick Guide 6 One 1 Regulatory Compliance Statement 1 3 Product Characteristics and Specifications 1 3 1 RFID Tag Supported by the MR11A7 The...

Страница 6: ...tion button Indicator Buzzer LED Vibrator Power Operation Voltage 3 7 VDC Working Current 450mA Standby Current 120mA Idle Current 100uA Battery 3 7V 1100mAh Lithium Battery Number of Scan per full ch...

Страница 7: ...second 3 short beeps Data Storage Failure Memory Full 1 flash 3 short beeps Data Transfer Failure Poor Connection Quality lit 1 second 4 short beeps Hi Lo Hi Lo Enters Configuration Mode BT Disconnec...

Страница 8: ...tton Function Button Blue Green Red LED Indicator Figure 1 1 Trigger Button and Function Button 1 4 2 Shut Down Method 1 By default MR11A7 shuts down automatically after 5 minutes of inactivity To adj...

Страница 9: ...ion Button once 2 Press and release Trigger Button once 3 Quickly repeat 1 and 2 for 5 cycles Afterwards the LED indicators of MR11A7 will be blinking in either of the below 2 colors each representing...

Страница 10: ...l flash continuously If the blue LED does not flash it means MR11A7 is not currently in Bluetooth Mode Please refer to Section 5 3 Communication Interface and change the Communication Interface to BT...

Страница 11: ...10 Step 3 In the Add a device window double click UHF RFID Reader to connect as per Figure 1 4 Figure 1 4 Select Bluetooth Device window...

Страница 12: ...licking Close the PC NB Bluetooth application Main Window will show UHF RFID Reader as a connected device as per Figure 1 6 Figure 1 5 Connection Successful message window Figure 1 6 PC NB Bluetooth a...

Страница 13: ...will flash continuously If the blue LED indicator does not flash it means MR11A7 is not currently in Bluetooth Mode Please refer to Section 5 3 Communication Interface and change the Communication In...

Страница 14: ...verable device list Step 4 Upon establishing connection the MR11A7 will emit two short beeps and turn off its blue LED indicator Also the UHF RFID Reader in the Apple iOS device s Bluetooth devices li...

Страница 15: ...1 11 Figure 1 11 UHF RFID Tag data will output to an app Step 6 If a virtual keyboard is required please press the Function Button once as per Figure 1 12 At this moment the MR11A7 will emit one short...

Страница 16: ...t is not currently in Bluetooth Mode Please refer to Section 5 3 Communication Interface and change the Communication Interface to BT HID Step 2 On the Android device go to Settings Bluetooth and turn...

Страница 17: ...vice s Bluetooth devices list will list as Connected as per Figure 1 15 Figure 1 15 The UHF RFID Reader now lists as Connected in the Bluetooth setup screen Step 5 Launch an app that can accept HID ke...

Страница 18: ...guage and Input Default and turn off the physical keyboard or in some cases turn on the on screen keyboard in the Select Input Method screen as shown in Figure 1 17 At this time the virtual keyboard w...

Страница 19: ...ltaneously lit for one second Reading Distance varies based on RFID tag s specifications and the different placement of tags Antenna Blue Green Red LED indicator Figure 1 18 Antenna LED Trigger Button...

Страница 20: ...Blue LED will start flashing as confirmation that it has cleared its Bluetooth pairing record Blue Green Red LED indicators Figure 1 20 Trigger Button and Function Button CAUTION 1 Please make sure bo...

Страница 21: ...in MR11A7 s memory The following steps will store or delete the data within A Retrieving the Data in Memory Step 1 After completing an RFID Tag read operation use a micro USB cable and connect the MR1...

Страница 22: ...ure 1 22 Copy the file TAGDATA TXT to the PC NB Step 4 Skip the following steps if you accept memory data stored in txt format Step 5 Open TAGDATA TXT using Excel In the Text Import Wizard Step 1 of 3...

Страница 23: ...nd click Next as per Figure 1 24 Figure 1 24 Text Import Wizard Step 2 of 3 dialogue box Step 7 In the Text Import Wizard Step 3 of 3 dialogue box if there are no special requirements directly click F...

Страница 24: ...ommunication Interface Figure 1 26 Memory data as shown in an Excel table B Deleting the Data in Memory To delete the data on MR11A7 s Memory please directly delete the file TAGDATA TXT in the removab...

Страница 25: ...ut releasing then press and hold the Trigger button as per Figure 2 1 After pressing both buttons for about 5 seconds the MR11A7 will emit two short beeps turn on Green LED indicator and enter Configu...

Страница 26: ...uration Mode it will emit 2 short beeps and turn off the Green LED indicator While within Wait Time pressing MR11A7 s Function button and then the Trigger button holding both buttons for about 5 secon...

Страница 27: ...11A7 2 Additional Functions area Communication Disconnect or change the COM port Retrieve Read MR11A7 s operation parameters Update Upload presently configured operation data etc For full details plea...

Страница 28: ...28 1 Software Version 2 Additional Functions 6 Exit 3 Settings Window 4 Suggestion Window 5 Connection Status Figure 3 2 Program Operation Main Window...

Страница 29: ...item to configure then double click the left mouse button or press Enter to enter the desired parameters setting window 4 1 Operation Mode Figure 4 2 Configure the Operation Mode for either Trigger M...

Страница 30: ...lease see 5 8 Sleep Mode Timer 2 Auto Mode Operation Method A The Auto Mode follows the same rules of operation as the Trigger Mode except that scan operation start automatically without pressing the...

Страница 31: ...S0 4 2 2 2 Target There are two Targets Single Target and Dual Target MR11A7 will read flag A if Single Target is selected and will read A first then read B if Dual Target is selected ConfigurationMe...

Страница 32: ...and Data Length must be set when User Memory is selected 4 2 5 1 Access Password Up to 8 digits of hexadecimal value can be entered if Access Password is required ConfigurationMethod set Access Passwo...

Страница 33: ...lick to s send the new parameter to the MR11A7 Default Setting 64 CAUTION The result of Multi Tag Read mode operation will vary because of the different placement of tags as well as the type of tags 4...

Страница 34: ...Time between every tag scan This feature may be disabled by setting Delay Time to 0 Disabled ConfigurationMethod Select a value 0 1500ms then click to transfer the new parameter value to the MR11A7 D...

Страница 35: ...ode Pattern 2 ConfigurationMethod Enable or Disable Included Filter Input the Start Bit of EPC Code by 4 bits 0 4 8 and the pattern string of Accepted Filter in hexadecimal then click to send the new...

Страница 36: ...hile two patterns Pattern 1 and Pattern 2 must be defined if Enable Range is selected Start Bit of EPC Code The start point by 4 bits from 0 4 8 to 248 of EPC Code to be compared Pattern 1 or Pattern...

Страница 37: ...the RF output power of MR11A7 Lower output power will result in shorter reading distance as well as more power saving ConfigurationMethod Select one RF output power level then click to send the new pa...

Страница 38: ...sable or Enable then click to send the new parameter values to the MR11A7 There are two output formats available one Full Description another Simple Cascade In Simple Cascade format the caption is neg...

Страница 39: ...rmats then click to send the new parameter values to the MR11A7 Default Setting Hexadecimal Note Please note that the Character conversion is only applicable for data ranging from 0x20 space to 0x7F d...

Страница 40: ...etting Disable 4 6 4 RSSI Received Signal Strength Indicator Whether to output tag s RSSI value Configuration Method Choose Disable or Enable Default Setting Disable If Output RSSI is enabled the foll...

Страница 41: ...tput EPC Scheme is enabled the following may also be configured 4 6 5 1 Output EPC Scheme caption EPC Scheme Configuration Method Choose Disable or Enable Default Setting Disable 4 6 6 EPC Code Whethe...

Страница 42: ...ether to output tags PC data This function is available when the EPC Code of Tag Info is selected Please see 4 2 2 and 4 2 5 Tag Info Configuration Method Choose Disable or Enable Default Setting Disa...

Страница 43: ...If Output CRC value is enabled the following may also be configured 4 6 8 1 Output CRC value s caption CRC Configuration Method Choose Disable or Enable Default Setting Disable 4 6 9 TID data Whether...

Страница 44: ...t tag s User memory This function is available when the User memory of Tag Info is selected Please see 4 2 2 Tag Info Configuration Method Choose Disable or Enable Default Setting Disable If output Us...

Страница 45: ...and 4 2 Read Mode Configuration Method Choose Disable or Enable Default Setting Disable 4 6 12 No Tag Message Whether to output No Tag Message No Tag Message is a preset message such as No Tag that di...

Страница 46: ...Figure 5 1 Figure 5 1 Other parameters not related to RFID 5 1 Date Format Figure 5 2 Date format of memory data s date mark Set how date format is arranged D means Date M means Month Y means Year 16...

Страница 47: ...emory data s time mark Set how time format is arranged H means Hour M means Minute S means Second 2 choices are available Configuration Method Choose one of the two then click to transfer the paramete...

Страница 48: ...ry When using Memory as the communication interface the MR11A7 will not output data scanned will store them within its internal memory as a file about 2MB in size To access that file a connection with...

Страница 49: ...symbol used to separate each field of data formatting ConfigurationMethod Directly input the symbol maximum 1 Byte in size then click to transfer the parameter value to the MR11A7 Default Setting Comm...

Страница 50: ...become available These include Key Layout Key Numeric Key Caps lock Inter block and Inter character 5 6 1 Keyboard Layout Figure 5 9 Set the language used for MR11A7 s data output to the Host PC 24 ch...

Страница 51: ...ter setting to the MR11A7 Default Setting Lock Off 5 6 4 Inter block Interval Time Figure 5 12 Sets the Interval Time between each packet of data including the separator symbol and the next Configurat...

Страница 52: ...fault 0x0D 0x0A Totals 2 Bytes 5 8 Sleep Mode Timer Set the activation status for Sleep Mode and the Timer value used for entering Sleep Mode The MR11A7 will enter Sleep Mode to conserve power if ther...

Страница 53: ...2 Beep Time Figure 5 18 Set the beep length for the short beep used to signify a Good Read Configuration Method Choose a value between 50 500 ms using 10 ms intervals Then click to transfer the parame...

Страница 54: ...on Mode Configuration Method Select a value between 1 60 minutes using 1 minute intervals Then click to transfer the parameter value to the MR11A7 Default Setting 5 minutes 5 12 System Time Set the MR...

Страница 55: ...ns include System Operation and Tools described as below 6 1 System A Communication When connected you may click Stop to get disconnected then change COM port and initiate another connection Figure 6...

Страница 56: ...ult Workplace Restores all defaults including window size font style font size etc 2 Usualness Font Mostly used for adjusting fonts for the Main Menu The user determines its use 3 Window Width Height...

Страница 57: ...7 is connected to the Host PC User can restore all parameters inside the MR11A7 to their factory Default settings Reset Reader s Parameter to Default Figure 6 5 CAUTION Reader s Communication Interfac...

Страница 58: ...58 6 3 Tools A Language Set the display language B Update the firmware on MR11A7 Please refer to 7 Updating Firmware on MR11A7...

Страница 59: ...nction button and the Trigger button on the MR11A7 as per Figure 7 1 Hold both buttons do not release and use a pin or a straightened paperclip to press the Reset button on the bottom as per Figure 7...

Страница 60: ...Execute the program Do not establish a connection Press to cancel the connection process and enter the program as per Figure 7 4 Cancel Connection Figure 7 4 Step 2 Choose and execute Please refer to...

Страница 61: ...ion Figure 7 7 CAUTION While the MR11A7 is updating its firmware Figure 7 8 please avoid unnecessary errors and do not unplug the cable Incomplete firmware update may cause damage to MR11A7 Figure 7 8...