5-4. Memory Communication Interface Options
When the Memory Communication Interface is chosen, each scanned data is marked with date and time,
and then stored in the internal memory. When the memory is full with data, Tag reading will elicit a warning
signal in the form of 3 short beeps and a one second lighting of the red LED indicator, and no reading will
actually occur. Only when the data inside the memory has been received and deleted by the Host PC may
the Scan Session resume. Choosing Memory as the Communication Interface enables the Field Separator
and Storage Sequence configuration options.
5-4-1. Field Separator
Figure 5-5
Sets the symbol used to separate each field for data formatting.
Configuration Method:
Directly input the symbol, maximum 1 Byte in size. Then click
to transfer the parameter value to the MR10A7.
Default setting: comma (,)
5-4-2. Storage Sequence
Figure 5-6
Sets the storage sequence of the fields Date, Time, Tag Data.
Configuration Method: For each Storage Sequence, choose one
of the options. No option may be chosen twice. When done,
click
to transfer the parameter setting to the MR10A7.
Default setting: Sequence - 1: Date
Sequence - 2: Time
Sequence - 3: Tag Data