Troubleshooting Tips
PROBLEM
CAUSE
SOLUTION
Rivet jammed
Wrong size rivet
Check nosepiece size versus rivet
Check for material in the jaw
housing
Remove the frame head and clear
debris from the inside
No suction
Shut off valve turned off
Remove the mandrel collector and
turn the vacuum adjustment knob
counterclockwise
Air leaking
Damaged O’rings
Replace damaged O’rings
Loss of power or tool runs slow
Air inlet assembly loose
Re-install and tighten air inlet
Exhaust port blocked
Clean debris from exhaust port
Low air pressure
Check pressure (85-95 psi)
Stroke has decreased
Loss of hydraulic oil in tool
Add hydraulic oil