marsden T-210 Скачать руководство пользователя страница 1

 
 

 
 
 
 
 
 
 
 
 
 
 
 
-

 

 
 
 

Version 1.7 10/20 

UFR118 (T-210)  

Infrared Thermometer 

 

User Manual

 

 

Содержание T-210

Страница 1: ...Version 1 7 10 20 UFR118 T 210 Infrared Thermometer User Manual...

Страница 2: ...f Conformity 3 Specification 4 Symbol Descriptions 4 Important Safety Instructions 5 Parts Identification 6 Battery Installation 7 About Normal Temperature Fever 8 Unit Setting 9 Operation 9 Error Mes...

Страница 3: ...11 2015 Medical electrical equipment Part 1 11 General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment and medical electrical...

Страница 4: ...t direct sunlight and water during transportation Expected Service Life Five years Software Version UFR 1 1 Symbol Descriptions The following symbols may appear in this manual on the label on the devi...

Страница 5: ...viduals The patrient is ther intended operator Temperature reading is for reference only CAUTION Please do not use a dilution agent alcohol or petrol to clean the unit Please use the device with care...

Страница 6: ...6 Parts Identification...

Страница 7: ...t socket or use a USB plug The device will need approximately eight hours to reach full charge A green strip will appear on the display during charging changing to a red strip when charging is complet...

Страница 8: ...t temperatures measured from different sites even at the same time should not be directly compared Fever indicates that the body temperature is higher than normal This symptom may be caused by infecti...

Страница 9: ...ce for 10 15 minutes prior to testing and room temperature should be 20 25 C To use the thermometer press the START STOP button All symbols will appear on the display and you will hear one short beep...

Страница 10: ...99 5 3 10 short beeps with red LED when measurement reading is 37 5 99 5 or higher 4 3 short beeps with red LED if the device is unable to measure temperature Babies skin reacts very quickly to ambien...

Страница 11: ...air under this warranty our authorised service agent must be advised of the fault within the period of the warranty This warranty only covers parts and labour service under normal operations Any defec...

Страница 12: ...quipment and result in improper operation Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches...

Страница 13: ...ected service life 2 Guidance and manufacturer s declaration electromagnetic emissions and immunity Table 1 Guidance and manufacturer s declaration electromagnetic emissions Emissions test Compliance...

Страница 14: ...ltage variations on power supply input lines IEC 61000 4 11 0 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 1 cycle And 70 25 30 cycles Single phase at 0 0 250 cycle 50Hz 0 0 5 cycle At 0 45 90 135 1...

Страница 15: ...1 8 0 3 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850...

Страница 16: ...364296 sales marsdengroup co uk Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX www marsden wei...

Отзывы: