Safety Instructions 

 

Before putting the device into use, please read with care the information given in this user manual, 
which contains important instructions for proper installation, use and maintenance of the device. 
 
Marsden/the manufacturer shall not be liable for damages arising from failure to heed the following 
instructions: 

 

When using electrical components under increased safety requirements, always comply with 
appropriate regulations. 

 

Inappropriate installation/use will render the warranty null and void. 

 

Ensure the voltage marked on the power supply unit matches your mains supply. 

 

This device is designed for use indoors. 

 

Observe the permissible ambient temperatures for use. 

 

The device meets the requirements for electromagnetic capability. Do not exceed the 
maximum values specified in the applicable standards. 

 

Batteries should be kept away from small children. If swallowed, promptly seek medical 
assistance. 

 
If you have any problems, contact Marsden/your local dealer/your service partner. 

 
 

Maintenance 

 

 

We recommend checking the scale

s accuracy at regular intervals. If any inaccuracies occur, 

please contact your local dealer or service partner. 

 

Repairs should be carried out by authorised service agents. For information regarding Marsden 
service contracts in the UK, call 01709 364296. 

 

Disposing of the Scale 

 

 

This product should not be treated as regular household waste, but should be handed in to an 
electrical/electronic equipment recycling centre. 

 

You can obtain further details from your local council, your municipal waste disposal company 
or from where you purchased the product. 

 

 
 
 
 

 

 

Page 4 

Содержание M-999

Страница 1: ...USER MANUAL M 999 Patient Transfer Scale Please take time to read these instructions before starting to use the scale Version 1 0 10 18...

Страница 2: ...c Symbols 6 LCD Display 7 Recharging the M 999 8 Setting up the Scale 9 Preparing to use the Scale 10 Operation Basic Functions 12 Operation Advanced Functions 13 EMC Guidance and Manufacturer s Decla...

Страница 3: ...e has a maximum load capacity of 250kg which must not be exceeded Product Specification Model M 999 Accuracy Class Class III Capacity Division 250kg x 0 5kg Weight of scale 11 4kg Units of Measure kg...

Страница 4: ...ts the requirements for electromagnetic capability Do not exceed the maximum values specified in the applicable standards Batteries should be kept away from small children If swallowed promptly seek m...

Страница 5: ...nt with detergent Use a non abrasive cloth Please do not use corrosive liquids large amounts of water or high pressure washers Do not submerge the PTS in water If you think the scale may have suffered...

Страница 6: ...Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C Identification of manufacturer of medical product including address Type B applied part Dispose of old appliances separately from your...

Страница 7: ...o indicator the weight reading is stable Minor weight The weight is under zero Zero symbol The weight is at zero point Low battery Please recharge the scale ON OFF ZERO Stable symbol Minus weight Zero...

Страница 8: ...ds recharging move the M 999 to a location where it can be charged You will find the charging port on the underside of the scale The port for the charging cable is magnetic Clip the end of the cable i...

Страница 9: ...or six seconds You will then enter Setup for auto power off buzzer and backlight Auto off time 30m 60 m off Buzzer On Off Backlight ON OFF Auto power off Buzzer on off Backlight on off To confirm the...

Страница 10: ...stors are applied before you begin the transfer process The distance between the bed and trolley bed must be no more than 100mm The Patient Transfer Scale must have a minimum of 200mm on each bed or t...

Страница 11: ...Page 11...

Страница 12: ...hows 0 0 the scale is ready to use Switching the Scale off Press and hold ON OFF ZERO button for three seconds to power the scale down Setting the Scale to Zero If for any reason the scale shows a rea...

Страница 13: ...fluctuations With a patient on the scale press HOLD The display will show HOLD NB Alternatively you can activate the Hold function before the patient is on the scale When the scale has determined the...

Страница 14: ...ity should be that of a typical commercial or hospital environment Guidance and manufacturer s declaration electromagnetic emissions The MEDICAL SCALE M 999 is intended for use in the electromagnetic...

Страница 15: ...power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m The MEDICAL SCALE M 999 power frequency magnetic fields should be at levels characteristic of a typical loc...

Страница 16: ...romagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephone...

Страница 17: ...W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8...

Страница 18: ...ed by a serious fault Please contact your service provider Counting error too low Indicates that the signal from the loadcell is too low This error is normally caused by a serious fault Please contact...

Страница 19: ...uropean standards following the provisions of the below stated directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive Please see separate document showing on sticker of device for abov...

Страница 20: ...ufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Sales Technical Support Service Finance Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX www m...

Отзывы: