Document No: QP-IOM
Date: 08/25/20
QuietPro 10 (QP10) COMMERCIAL SERIES
Installation, Operation and Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with these
instructions could result in personal injury and/or property damage. Retain these instructions for future reference.
OVERVIEW
Mars Air Curtains are
designed to cover door
openings, providing
both temperature
control/environmental
separation and flying
insect control, when the
building’s doors are
opened.
Typical
installation heights are:
QuietPro 10 Series
(Environmental
Separation up to 12’,
Flying Insect Control up
to 10’). The units are
typically wall mounted
horizontally above the door opening. They can also be
suspended from the ceiling or vertically mounted
alongside the opening. The units are ETL Listed, Canada
and US, for either an inside or outside mount. Heated
units must be mounted on the inside or the protected side
of the opening. The motors used in the QuietPro 10
series are 1/2 HP.
QuietPro 10 come standard with an air intake screen(s).
They can also be configured with an aluminum mesh air
intake filter instead of the air intake grille or in conjunction
with it.
GENERAL SAFETY
INFORMATION
Use this product only in
the manner intended by
the manufacturer. Only
qualified personnel
should install this
product. Installing
personnel should have a
clear understanding of
these instructions and
should be aware of
general safety
precautions. Improper
installation can result in
electric shock, possible
injury due to coming in
contact with moving parts, as well as other potential
hazards.
WARNING
To reduce the risk of fire, electric shock, or injury to
persons, observe the following.
A. Always disconnect, lock and tag power source before
installing or servicing product.
B. Installation work or electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
C. The combustion airflow needed for safe operation of
fuel burning equipment in the area may be affected by
the product’s operation. Follow the heating equipment
manufacturer’s guideline and safety standards, such
as those published by the National Fire Protection
Agency (NFPA), the American Society of Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE) and local code authorities.
D. When cutting or drilling into a wall or ceiling, be careful
not to damage electrical wiring and other hidden
utilities.
WARNING
When servicing the product, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.