![MARS COMMERCE SOLO-NX Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/mars-commerce/solo-nx/solo-nx_instruction-manual_1730649024.webp)
SOLO-NX
INSTALLATION MANUAL
Page 24
9.9
EVENT LOGGING
SOLO-NX device support logging of specific events. SOLO-NX logs CLIP event and alarm input
events. Log event consist of event type, time and telephone number or input number.
Up to 20.000 Log events can be stored.
9.9.1
LOGN parameter
Parameter is used for defining the number of events printed out on PLOG request.
9.9.2
LOGI parameter
Parameter is used to define the media used for logging of events on SOLO-NX. User can select
between nonvolatile memory on SOLO-NX or select USB to transfer events directly via USB to
PC.
LOGI=0 Logging is OFF
LOGI=1 Logging in internal memory
LOGI=2 Logging to USB interface
9.9.3
ALC parameter
Parameter is used to control behavior when log on SOLO-NX is full. User can select between auto
log clear or manual clear of log.
ALC=0 Automatically delete buffer when memory is FULL
ALC=1 Memory buffer must be deleted manually when it is FULL
9.9.4
Table of parameters
Name
Comment
LOGN
Number of log events for printing out
LOGI
Log interface
ALC
Automatic log clear
Table 20: LOG parameters.
Example:
Direct programming on the SIM card
SOLO-NX PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
LOGN
5
5 log events will be printed out on PLOG command
LOGI
0
Nonvolatile memory on SOLO-NX
ALC
1
Log is auto cleared when full
Table 21: LOG parameters example.
Remote programming by SMS
;LOGN=5;LOGI=0;ALC=1;