SOLO-NX
EXT
INSTALLATION MANUAL
Page 10
9.1.2.3
LOT parameter
LOT parameter is used to define the time control for voice calls. The start of voice connection starts
the LOT timer. If the voice connection is still ON when the LOT timer expires SOLO-NX
disconnects voice connection.
9.1.2.4
Table of parameters
Name
Comment
TN1
1
st
telephone number
TN2
2
nd
telephone number
TN3
3
rd
telephone number
TN4
4
th
telephone number
TN5
5
th
telephone number
LN1
Input & telephone No. linking for 1
st
alarm input (TN1 – TN5)
LN2
Input & telephone No. linking for 2
nd
alarm input (TN1 – TN5)
LN5
Periodic test SMS. No. linking (TN1 – TN5)
LN6
SIM card refill. No. linking (TN1 – TN5)
LN7
NAC list. No. linking (TN1 – TN5) (see note)
LN8
Log status. No. linking (TN1 – TN5)
LOT
Time out for GSM connection.
Table 3: Remote alarm reporting parameters
NOTE
When telephone number (calling or messaging SOLO-NX) is not on the CLIP list, not
acknowledge event occurs (NAC). The telephone number responsible for this event
can be send to TN user for notification.
Example:
Direct programming on the SIM card
SOLO-NX PROGRAMMING TABLE
Name
Number
Description
TN1
042376678 1st telephone number
LN1
13
Input 1 reports alarm to TN1 & TN3
LN2
1234
Input 2 reports alarm to TN1 & TN2 & TN3 & TN4
LN7
1
NAC event sent to TN1
LOT
60
Voice connection stay valid for max of 60s, after this time
Voice connection breaks
Table 4: Remote alarm reporting example
Remote programming by SMS
;TN1=042376678;LN1=13;LN2=1234;LN7=1;LOT=60;