Trawl Explorer | V5 | Servicing and Maintenance
5.
Click
Download Depth Programmer
.
The XML file is downloaded in the
Downloads
folder.
6.
Connect the sensor to Mosa2.
7.
From Mosa2, click
Menu
>
Expert Mode
and enter the password
copernic
.
8.
From the tab
General
, click
Depth coefficients
.
9.
Click
Browse
and select the xml file you downloaded.Click
Apply
.
The pressure coefficients are updated.
Replacing the Temperature Sensor
Before you begin
For this task you need the following tools:
Allen keys:
1.5 mm, 1/8"
22 mm
wrench
Tweezers
Wire stripper
Crimping tool
O-ring
lubricant
(Molykote 55
o-ring grease)
Loctite 425
About this task
Only qualified Marport technicians can do this task.