Trawl Explorer | V5 | Sensor Configuration
Configuring Measurement Sending Sequence and True Mode
If you use the True Mode display for echograms in Scala/Scala2, you need to select a specific
sequence of measurements (e.g. temperature, pitch, roll...) sent by the uplink to the receiver.
Before you begin
The sensor is connected to Mosa2.
Procedure
1.
From Mosa2, click
Menu
>
Expert Mode
and enter the password
copernic
.
2.
Click the tab
Trawl Explorer
.
3.
From
Option True Mode
, select a sequence from
True Mode Option
.
• Select
Config1
(default): this is the more appropriate sequence for a Trawl Explorer.
• Or select
Config3
if you use the True mode display on echograms in Scala/Scala2.
4.
Click
Apply
.
Below is an example of echograms without True Mode (top) and with True Mode (bottom). With
True Mode activated, you see the area between the sea surface and the seabed. This way, you
can see the trawl descent. See Scala/Scala2 user guide for more information.