Copyright by Servizio Clienti ANGELO PO Spa
98
4.4.4.
Adjustment during the test
4.4.4.1. Values of the minimum ignition failure:
Offset Adjust gas valve (PR.ADJ.)
If the combustion values at minimum power do not correspond
to the recommended offset adjusting of the valve is needed.
To do this with a screwdriver unscrew the protective brass cap
and take a 4mm Allen wrench.
At this point, if the CO2 is lower than the recommended value,
screw clockwise (see figure at right), to enrich the mixture.
If the CO2 is higher unscrew slowly to lessen the mixture.
The adjustment is very sensitive and you should make small movements (a quarter turn
rotation involves a variation of about 1% CO2) and wait for the gas analyzer to detect the
change and stabilize.
Once done repeat the wizard test.
When the adjustment is finished refit the protective cap of the screw.
Attention: the pressure adjustment screw PR.ADJ. has no effect on
increasing the power of the oven.
In case of change without written permission by Angelo Po, the
warranty will be void
Содержание ANGELO PO COMBISTAR FX
Страница 1: ...1 Rev 0 ...
Страница 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Страница 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Страница 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Страница 14: ...Copyright by Servizio Clienti ANGELO PO Spa 14 2 FUNCTIONAL DIAGRAM COMBI OVEN 6 7 10 1 9 5 11 12 13 14 15 ...
Страница 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Страница 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Страница 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Страница 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Страница 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Страница 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Страница 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Страница 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...