4.4. Gas Test
4.4.1.
Polarity check
During the installation,
it’s necessary to respect the correct connection of PHASE and
NEUTRAL (not inverted). If the connection is inverted the microAmpere reading of the
flame detector will be lower as it should be. To check, remember that the voltage
measured between
NEUTRAL
and
EARTH
is
0±10Vac
4.4.2.
Gas conversion
All equipment is tested and adjusted to work with Natural gas (G20), where it is required to
use a different type of gas follow the instruction below:
1.
Gas nozzle replacement
: Unscrew the gas pipe (Pic 1), remove the Natural gas
(G20) nozzle and put in place the replacement nozzle (Pic 2), then tighten the pipe.
The nozzle works also as seal.
The nozzle must be mounted as shown in pic 3.
PICTURE 1
PICTURE 2
PICTURE 3
Содержание ANGELO PO BX101E
Страница 1: ...1 Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Страница 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Страница 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Страница 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Страница 62: ...Copyright by Servizio Clienti ANGELO PO Spa 62 MAGNET POSITION DURING THE COMBUSTION FUME COLLECTION...
Страница 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Страница 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Страница 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...