Copyright by Servizio Clienti ANGELO PO Spa
109
6.10.
Blower fan replacement
To replace the blower fan follow the instruction below:
1. Unscrew the 3 screws, then the 4 nuts on the bench (PIC 1)
2. Unscrew the 2 front screws and loosen the rear one (PIC 2)
3. Disconnect the wires and replace the blower fan
NOTE
: when replacing check that the size of diaphragm installed is correct (see picture 3
and table)
Diaphragm
FX-BX 61G
FX-BX 101G
FX-BX 82G
FX-BX 122G
Ø16 - 3138640
Ø20 - 3138660
Ø24 - 3138650
Ø30 - 3138670
Diaphragm
2018
FX-BX 61G
FX-BX 101G
FX-BX 82G
FX-BX 122G
Ø14,5 - 3360000
Ø20 - 3320480
Ø23 - 3371590
Ø30 - 3320450
PIC 1
PIC 2
PIC 3