background image

SPECIFICATIONS

Model

Dimensions

Wire Ga.

Number

Volts

Watts

Amps

BTU

A Length

B Width

D Depth

(Min.)

N1011B

120

8.3

N1081B

208

4.8

27.125”

8.375”

3.5”

N1021B

240

1000

4.2

3412

(689 mm)

(212 mm)

(88.9)

14 Ga.

N1511B

120

12.5

N1581B

208

7.2

35.625”

8.375”

3.5”

N1521B

240

1500

6.3

5118

(905 mm)

(212 mm)

(88.9)

14 Ga.

N1571B

277

5.4

N1531B

347

4.3

N2001B

208

9.6

N2021B

240

2000

8.3

6824

46.625”

8.375”

3.5”

14 Ga.

N2071B

277

7.2

(1184 mm) (212 mm)

(88.9)

N2031B

347

5.8

N2501B

208

12.0

N2521B

240

2500

10.4

8530

53.375”

8.375”

3.5”

14 Ga.

N2571B

277

9.0

(1356 mm) (212 mm)

(88.9)

N2531B

347

7.2

INSTALLATION

The  Marley  Engineered  Products  N

Series  radiant  heater  is  shipped  fully
assembled.  The  heater  can  be  hung  from
the ceiling by chains or rigid angle brackets
attached to the heater 
brackets located on the back of the heater.
Hanging  chain  kits  are  available  for  these
heaters  that  will  allow  for  installations  to  6
feet from the ceiling.) (

Model MHK

)

Minimum spacings:

Ceiling to top of heater is 3 in.
Wall to sides of heater is 12 in.
Floor to bottom of heater is 10 feet. 

Installer  should  consult  state  and  local
codes and meet any applicable 
requirements regarding the installation.

a

CAUTION

Ø1.125

SERVICE

ENTRANCE

OPENING

4X1/4" Ø MOUNTING
HOLE FOR "S" HOOKS

1.000

±

.062

(3.500)

90˚

(8.375)

(4.500)

(10.000)

Ø.475

VIEW SHOWN WITH
COVER REMOVED

("B")

("A")

Figure 1

TOP VIEW

Heater

Wall

Wall

12" (304.8mm) Min.

12" (304.8mm) Min.

SIDE VIEW

Wall

Floor

Ceiling

Chain

3" (76.2mm) Min.

10' (3048mm) Min.

Figure 2

2

!

Содержание N1011B

Страница 1: ...n against possible electric shock 3 Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing 4 This heater is NOT suitable for use in hazardous loca tions as described by the National Fire Protection Association NFPA This heater has hot and arcing or sparking parts inside DO NOT use in areas where gasoline paint or other flammable liqui...

Страница 2: ...ter is shipped fully assembled The heater can be hung from the ceiling by chains or rigid angle brackets attached to the heater brackets located on the back of the heater Hanging chain kits are available for these heaters that will allow for installations to 6 feet from the ceiling Model MHK Minimum spacings Ceiling to top of heater is 3 in Wall to sides of heater is 12 in Floor to bottom of heate...

Страница 3: ...g size 6 Heater can be wired with rigid or flexible conduit ELECTRIC SHOCK HAZARD Disconnect all power before installing or servicing heater Failure to do so could result in personal injury or property damage Heater must be effectively grounded in accordance with the National Electrical Code NFPA 70 a WARNING All electrical wiring must be done by a qualified person in accordance with National Elec...

Страница 4: ...units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center and we will repair or replace at our option at no charge to you with return freight paid by Marley It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED O...

Отзывы: